Literature DB >> 9674677

Clinical comparison and performance perspective of three aligning arch wires.

T J Evans1, M L Jones, R G Newcombe.   

Abstract

OBJECTIVES: To clinically evaluate three commonly used orthodontic tooth aligning arch wires: 016 x 022 inch active martensitic medium force nickel titanium, 016 x 022 inch graded force active martensitic nickel titanium, and 0.0155 inch multistrand stainless steel.
DESIGN: A prospective randomized clinical trial. DATA SOURCE: Measured serial study casts of dental arches for 112 assigned arch wires from 56 consecutive patients. Analysis based on completed records for 98 arch wires and 51 patients.
METHOD: A consecutive sample of 56 patients requiring both upper and lower fixed appliance therapy were randomly allocated two different arch wires from a possible three under trial. Good quality impressions were taken of the dental arches at the designated serial stages of alignment (start, T0; 4 weeks, T4; 8 weeks, T8). The resultant casts were measured on a Reflex Microscope to record the change in individual tooth alignment both in three and two dimensions (horizontal plane only).
RESULTS: The measurement error was within acceptable limits (range, 0.05 to 0.09 mm) and showed no significant bias. ANOVA statistical models were fitted to the data to adjust for a number of variables. No significant difference in aligning capability (p > 0.05), in either two or three dimensions, was demonstrated between the three arch wires in the trial.
CONCLUSION: Heat activated nickel titanium arch wires failed to demonstrate a better performance than the cheaper multistrand stainless steel wires in this randomized clinical trial. The failure to demonstrate in vivo superiority at the clinical level may be due to the confounding effects of large variations in individual metabolic response. Alternatively, it may be that in routine clinical practice NiTi-type wires are not sufficiently deformed to allow their full superelastic properties to come in to play during initial alignment.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9674677     DOI: 10.1016/s0889-5406(98)70234-3

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  11 in total

Review 1.  Which Orthodontic Wire and Working Sequence Should be Preferred for Alignment Phase? A Review.

Authors:  Sedef Sera Hepdarcan; R Burcu Nur Yılmaz; Didem Nalbantgil
Journal:  Turk J Orthod       Date:  2016-06-01

2.  Comparison of Superelasticity of Nickel Titanium Orthodontic Arch wires using Mechanical Tensile Testing and Correlating with Electrical Resistivity.

Authors:  Aravind Sivaraj
Journal:  J Int Oral Health       Date:  2013-06-23

3.  Alignment efficiency of superelastic coaxial nickel-titanium vs superelastic single-stranded nickel-titanium in relieving mandibular anterior crowding: a randomized controlled prospective study.

Authors:  Biju Sebastian
Journal:  Angle Orthod       Date:  2011-10-19       Impact factor: 2.079

4.  Efficiency, behavior, and clinical properties of superelastic NiTi versus multistranded stainless steel wires: a prospective clinical trial.

Authors:  Satpal S Sandhu; V Surendra Shetty; Subraya Mogra; Joseph Varghese; Jasleen Sandhu; Jagpreet S Sandhu
Journal:  Angle Orthod       Date:  2012-01-06       Impact factor: 2.079

5.  A clinical comparison of three aligning archwires in terms of alignment efficiency: A prospective clinical trial.

Authors:  Reem Sh Abdelrahman; Kazem S Al-Nimri; Emad F Al Maaitah
Journal:  Angle Orthod       Date:  2014-08-04       Impact factor: 2.079

6.  Alleviation of Lower Anterior Crowding with Super- Elastic and Heat-Activated NiTi Wires: A Prospective Clinical Trial.

Authors:  Pasupureddi Keerthana; Prasad Chitra
Journal:  Turk J Orthod       Date:  2021-06

Review 7.  Initial arch wires used in orthodontic treatment with fixed appliances.

Authors:  Yan Wang; Chang Liu; Fan Jian; Grant T McIntyre; Declan T Millett; Joy Hickman; Wenli Lai
Journal:  Cochrane Database Syst Rev       Date:  2018-07-31

8.  Arch Expansion Efficiency of Coaxial Tubular Superelastic Nickel-Titanium in Comparison to Single-Stranded Superelastic Nickel-Titanium While Relieving Mandibular Anterior Crowding: A Randomized Controlled Study.

Authors:  Joe Joseph; Vivek Suku Ninan; Merin Elsa Abraham; Jacob John; Karun Koshy Cherian; Reema Mary Thomas
Journal:  J Int Soc Prev Community Dent       Date:  2019-02-14

9.  A comparative in-vivo evaluation of the alignment efficiency of 5 ligation methods: A prospective randomized clinical trial.

Authors:  Vijaya Bhaskara Reddy; Talapaneni Ashok Kumar; Mandava Prasad; Sivakumar Nuvvula; Rajedra Goud Patil; Praveen Kumar Reddy
Journal:  Eur J Dent       Date:  2014-01

10.  A randomized clinical trial investigating pain associated with superelastic nickel-titanium and multistranded stainless steel archwires during the initial leveling and aligning phase of orthodontic treatment.

Authors:  Satpal Singh Sandhu; Jasleen Sandhu
Journal:  J Orthod       Date:  2013-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.