Analysis of the kinematics of different hip simulators used to study wear of candidate materials for the articulation of total hip arthroplasties.

B S Ramamurti1, D M Estok, M Jasty, W H Harris.   

Abstract

We developed an analytical technique to determine the paths traced by specific points on the femoral head against the acetabulum in the human hip joint during gait. The purpose of the study was to apply this technique to the mechanical hip simulators chosen to conduct wear tests on polymeric acetabular liners used in total hip replacements. These simulators differ from one another in the type of motion produced, apart from other variables such as type of lubricant and head position. Due to the variation in the kinematics between the machines, the paths traced by the points on the femoral head against the acetabular liner ranged from simple linear traces to figure-8 loops and quasi-elliptical paths during a single simulator cycle. The distances traveled by these points during the same period also varied appreciably among the different hip simulator designs. These results are important when combined with other studies that have shown that kinematics can play an important role in the outcome of in vitro wear experiments. The kinematic differences quantified in this study can partially explain the substantial differences in wear data reported from different simulator designs and also underscore the usefulness of the technique described in this study in judging the results from different hip simulator experiments.

Entities:  

Mesh:

Year:  1998        PMID: 9671932     DOI: 10.1002/jor.1100160313

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  3 in total

1.  Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E.

Authors:  Ebru Oral; Steven D Christensen; Arnaz S Malhi; Keith K Wannomae; Orhun K Muratoglu
Journal:  J Arthroplasty       Date:  2006-06       Impact factor: 4.757

2.  Alumina-on-alumina ceramic versus metal-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a comparative study.

Authors:  Zoran Bascarevic; Zoran Vukasinovic; Nemanja Slavkovic; Borislav Dulic; Goran Trajkovic; Violeta Bascarevic; Sladjan Timotijevic
Journal:  Int Orthop       Date:  2009-11-01       Impact factor: 3.075

3.  Sliding direction dependence of polyethylene wear for metal counterface traverse of severe scratches.

Authors:  Liam P Glennon; Thomas E Baer; James A Martin; William D Lack; Thomas D Brown
Journal:  J Biomech Eng       Date:  2008-10       Impact factor: 2.097

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.