Literature DB >> 9671170

Immune complex transfer enzyme immunoassay for antibody IgG to HIV-1 gp41 antigen using synthetic peptides as antigens.

S Hashida1, S Ishikawa, K Hashinaka, I Nishikata, S Oka, E Ishikawa.   

Abstract

The immune complex transfer enzyme immunoassay for antibody IgG to HIV-1 gp41 antigen was developed using two synthetic peptides. An aliquot (10 microl) of serum samples from HIV-1 seropositive subjects was incubated simultaneously with 2,4-dinitrophenyl-bovine serum albumin-synthetic HIV-1 gp41 peptide conjugates and synthetic HIV-1 gp41 peptide-beta-D-galactosidase conjugates and subsequently with colored polystyrene beads coated with affinity-purified (anti-2,4-dinitrophenyl group) IgG to trap the immune complexes formed comprising the three components. After washing, the colored polystyrene beads were incubated with white polystyrene beads coated with affinity-purified (anti-human IgGgamma-chain) IgG in the presence of epsilonN-2,4-dinitrophenyl-L-lysine to transfer the immune complexes to the white polystyrene beads. Beta-D-Galactosidase activity bound to the white polystyrene beads was assayed by fluorometry. The formation, trapping and transferring of the immune complexes were completed within 0.5, 0.5 and 1.5 hr, respectively. Since each peptide appeared to react with its own specific antibody IgG, serum samples were tested by the equimolar combination of the two peptides. The lowest signals (fluorescence intensities for bound beta-D-galactosidase activity) for serum samples from HIV-1 asymptomatic carriers, patients with AIDS-related complex and patients with AIDS were 1490-, 2210- and 1460-fold, respectively, higher than the highest signal for serum samples from HIV-1 seronegative subjects. In five seroconversion serum panels, antibody IgG to HIV-1 gp41 antigen was detected as early as antibodies to HIV-1 detected by three currently commercially available methods.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9671170      PMCID: PMC6807746     

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  13 in total

1.  A centrifuged-column procedure for the measurement of ligand binding by beef heart F1.

Authors:  H S Penefsky
Journal:  Methods Enzymol       Date:  1979       Impact factor: 1.600

Review 2.  Diagnosis of HIV-1 infection by detection of antibody IgG to HIV-1 in urine with ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) using recombinant proteins as antigens.

Authors:  S Hashida; K Hashinaka; A Saitoh; A Takamizawa; H Shinagawa; S Oka; K Shimada; K Hirota; T Kohno; S Ishikawa
Journal:  J Clin Lab Anal       Date:  1994       Impact factor: 2.352

3.  Diagnosis of HIV-1 infection with whole saliva by detection of antibody IgG to HIV-1 with ultrasensitive enzyme immunoassay using recombinant reverse transcriptase as antigen.

Authors:  S Ishikawa; S Hashida; K Hashinaka; K Hirota; A Saitoh; A Takamizawa; H Shinagawa; S Oka; K Shimada; E Ishikawa
Journal:  J Acquir Immune Defic Syndr Hum Retrovirol       Date:  1995-09-01

4.  Whole saliva dried on filter paper or diagnosis of HIV-1 infection by detection of antibody IgG to HIV-1 with ultrasensitive enzyme immunoassay using recombinant reverse transcriptase as antigen.

Authors:  S Ishikawa; S Hashida; K Hashinaka; K Hirota; M Kojima; A Saito; A Takamizawa; H Shinagawa; S Oka; K Shimada; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1996       Impact factor: 2.352

5.  More sensitive immune complex transfer enzyme immunoassay for antibody IgG to p17 of HIV-1 with shorter incubation time for immunoreactions and larger volumes of serum samples.

Authors:  S Ishikawa; S Hashida; K Hashinaka; M Kojima; A Saito; A Takamizawa; H Shinagawa; S Oka; K Shimada; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1997       Impact factor: 2.352

Review 6.  Enzyme-labeling of antibodies and their fragments for enzyme immunoassay and immunohistochemical staining.

Authors:  E Ishikawa; M Imagawa; S Hashida; S Yoshitake; Y Hamaguchi; T Ueno
Journal:  J Immunoassay       Date:  1983

7.  Detection of antibody IgG to HIV-1 in urine by ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) using recombinant p24 as antigen for diagnosis of HIV-1 infection.

Authors:  S Hashida; K Hashinaka; K Hirota; A Saitoh; A Nakata; H Shinagawa; S Oka; K Shimada; J Mimaya; S Matsushita
Journal:  J Clin Lab Anal       Date:  1994       Impact factor: 2.352

8.  Measurement of human immunodeficiency virus type 1 p24 in serum by an ultrasensitive enzyme immunoassay, the two-site immune complex transfer enzyme immunoassay.

Authors:  S Hashida; K Hashinaka; I Nishikata; S Oka; K Shimada; A Saitoh; A Takamizawa; H Shinagawa; E Ishikawa
Journal:  J Clin Microbiol       Date:  1995-02       Impact factor: 5.948

9.  Immune complex transfer enzyme immunoassay that is more sensitive and specific than western blotting for detection of antibody immunoglobulin G to human immunodeficiency virus type 1 in serum with recombinant pol and gag proteins as antigens.

Authors:  S Hashida; K Hashinaka; I Nishikata; S Oka; K Shimada; A Saito; A Takamizawa; H Shinagawa; S Yano; H Kojima
Journal:  Clin Diagn Lab Immunol       Date:  1995-09

10.  Detection of anti-human immunodeficiency virus type 1 (HIV-1) immunoglobulin G in urine by an ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) with recombinant reverse transcriptase as an antigen.

Authors:  K Hashinaka; S Hashida; K Hirota; A Saitoh; A Nakata; H Shinagawa; S Oka; K Shimada; E Ishikawa
Journal:  J Clin Microbiol       Date:  1994-03       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.