Literature DB >> 9667290

Lumbosacral cerebrospinal fluid volume is the primary determinant of sensory block extent and duration during spinal anesthesia.

R L Carpenter1, Q H Hogan, S S Liu, B Crane, J Moore.   

Abstract

UNLABELLED: BACKGROUND. Injection of local anesthetic into cerebrospinal fluid (CSF) produces anesthesia of unpredictable extent and duration. Although many factors have been identified that affect the extent of spinal anesthesia, correlations are relatively poor and the extent of spread remains unpredictable. This study was designed to determine whether variability in the volume of lumbosacral CSF among individuals is a contributing factor in the variability of spinal anesthesia.
METHODS: Spinal anesthesia was administered to 10 healthy volunteers with 50 mg lidocaine in 7.5% dextrose. The technique was standardized to minimize variability in factors known to affect the distribution of spinal anesthesia. The extent of sensory anesthesia was assessed by pin-prick and by transcutaneous electrical stimulation. Motor blockade was assessed in the quadriceps and gastrocnemius muscles by force dynamometry. Duration of anesthesia was assessed by pinprick, transcutaneous electrical stimulation, and duration of motor blockade. Lumbosacral CSF volumes were calculated from low thoracic, lumbar, and sacral axial magnetic resonance images obtained at 8-mm increments. Volumes of CSF were correlated with measures of extent and duration of spinal anesthesia using the Kendall rank correlation test.
RESULTS: Lumbosacral CSF volumes ranged from 42.7 to 81.1 ml. Volumes of CSF correlated with pin-prick assessments of peak sensory block height (P = 0.02) and duration of surgical anesthesia (as assessed by the duration of tolerance to transcutaneous electrical stimulation at the ankle (P < 0.05).
CONCLUSIONS: Variability in lumbosacral CSF volume is the most important factor identified to date that contributes to the variability in the spread of spinal sensory anesthesia.

Entities:  

Mesh:

Year:  1998        PMID: 9667290     DOI: 10.1097/00000542-199807000-00007

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  43 in total

1.  Ketamine impairs excitability in superficial dorsal horn neurones by blocking sodium and voltage-gated potassium currents.

Authors:  Rose Schnoebel; Matthias Wolff; Saskia C Peters; Michael E Bräu; Andreas Scholz; Gunter Hempelmann; Horst Olschewski; Andrea Olschewski
Journal:  Br J Pharmacol       Date:  2005-11       Impact factor: 8.739

2.  Influence of lateral decubitus positioning after combined use of hyperbaric and hypobaric ropivacaine on hemodynamic characteristics in spinal anesthesia for caesarean section.

Authors:  Zhe-Feng Quan; Hai-Li He; Ming Tian; Ping Chi; Xin Li
Journal:  Int J Clin Exp Med       Date:  2014-12-15

3.  The impact of body mass index on the risk of high spinal block in parturients undergoing cesarean delivery: a retrospective cohort study.

Authors:  Agnes M Lamon; Lisa M Einhorn; Mary Cooter; Ashraf S Habib
Journal:  J Anesth       Date:  2017-04-18       Impact factor: 2.078

4.  Lower-Dose Mepivacaine Plus Fentanyl May Improve Spinal Anesthesia for Knee Arthroscopy.

Authors:  Richard L Kahn; Jennifer Cheng; James J Bae; Kara Fields; John G Muller; John D MacGillivray; Howard A Rose; Riley J Williams; Jacques T YaDeau
Journal:  HSS J       Date:  2015-07-09

5.  Population Pharmacokinetic-Pharmacodynamic Modeling of Ropivacaine in Spinal Anesthesia.

Authors:  Zoubir Djerada; Catherine Feliu; Yoann Cazaubon; Faouzi Smati; Philippe Gomis; Dominique Guerrot; Beny Charbit; Olivier Fernandes; Jean-Marc Malinovsky
Journal:  Clin Pharmacokinet       Date:  2018-09       Impact factor: 6.447

6.  The effect of body mass index on the spread of spinal block in patients with rheumatoid arthritis.

Authors:  Kari A Leino; Kristiina S Kuusniemi; Heikki K Pälve; Hannu T Tiusanen; Tapani T Tuppurainen
Journal:  J Anesth       Date:  2010-12-31       Impact factor: 2.078

7.  Adverse drug reactions to local anaesthetics: a review of the French pharmacovigilance database.

Authors:  Régis Fuzier; Maryse Lapeyre-Mestre; Kamran Samii; Jean-Louis Montastruc
Journal:  Drug Saf       Date:  2009       Impact factor: 5.606

8.  [Secondary cranial extension after spinal anesthesia with isobaric 0.5% bupivacaine following postural change].

Authors:  O Vicent; R J Litz; M Hübler; T Koch
Journal:  Anaesthesist       Date:  2003-11       Impact factor: 1.041

9.  Large intrathecal volume: a cause of true failed spinal anesthesia.

Authors:  Joan E Spiegel; Philip Hess
Journal:  J Anesth       Date:  2007-08-01       Impact factor: 2.078

Review 10.  Neuraxial analgesia in neonates and infants: a review of clinical and preclinical strategies for the development of safety and efficacy data.

Authors:  Suellen M Walker; Tony L Yaksh
Journal:  Anesth Analg       Date:  2012-07-13       Impact factor: 5.108

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.