Validation of the Takeda 2421 ambulatory blood pressure monitor in children.

J J O'Sullivan1, G Derrick, P E Griggs, C Wren.   

Abstract

The purpose of this study was to assess the accuracy of an ambulatory monitor (Takeda 2421; A&D company) which measures blood pressure using oscillometric and Korotkoff methods, in children. Blood pressure was measured simultaneously by the device and two observers in 529 children aged 7-15 years. The Korotkoff method received BHS grade A for sitting and standing readings in all age groups except for age 13-15 years (grade C). The diastolic readings (phase V) received grade B for sitting and C when standing. The oscillometric method received grade C or worse for systolic and diastolic blood pressure in both sitting and standing positions except for systolic readings in those aged 13-15 years (grade B). During the ambulatory phase 30% of the Korotkoff readings and 4% of the oscillometric readings gave an error code. The Takeda 2421 ambulatory monitor achieved generally satisfactory grades using the Korotkoff system but the oscillometric readings were generally unacceptable. Ambulatory devices should be specifically validated in children before being accepted into clinical paediatric practice.

Entities:  

Mesh:

Year:  1998        PMID: 9667035     DOI: 10.3109/03091909809062474

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  8 in total

1.  Measurement and interpretation of blood pressure.

Authors:  C D Goonasekera; M J Dillon
Journal:  Arch Dis Child       Date:  2000-03       Impact factor: 3.791

2.  Blood pressure measuring devices: recommendations of the European Society of Hypertension.

Authors:  E O'Brien; B Waeber; G Parati; J Staessen; M G Myers
Journal:  BMJ       Date:  2001-03-03

3.  Ambulatory blood pressure in schoolchildren.

Authors:  J J O'Sullivan; G Derrick; P Griggs; R Foxall; M Aitkin; C Wren
Journal:  Arch Dis Child       Date:  1999-06       Impact factor: 3.791

4.  Masked Isolated Nocturnal Hypertension in Children and Young Adults.

Authors:  Hisayo Fujita; Seiji Matsuoka; Midori Awazu
Journal:  Pediatr Cardiol       Date:  2017-09-25       Impact factor: 1.655

Review 5.  Utility of ambulatory blood pressure monitoring in children and adolescents.

Authors:  John W Graves; Mohammed Mahdi Althaf
Journal:  Pediatr Nephrol       Date:  2006-07-06       Impact factor: 3.714

6.  Visit-to-visit blood pressure variability in children and adolescents with renal disease.

Authors:  Hisayo Fujita; Seiji Matsuoka; Midori Awazu
Journal:  Clin Exp Nephrol       Date:  2018-03-14       Impact factor: 2.801

Review 7.  Ambulatory blood pressure monitoring: a versatile tool for evaluating and managing hypertension in children.

Authors:  Alisa A Acosta; Karen L McNiece
Journal:  Pediatr Nephrol       Date:  2008-02-23       Impact factor: 3.714

8.  Prevalence of hypertension in children after early repair of coarctation of the aorta: a cohort study using casual and 24 hour blood pressure measurement.

Authors:  J J O'Sullivan; G Derrick; R Darnell
Journal:  Heart       Date:  2002-08       Impact factor: 5.994

  8 in total