Literature DB >> 9663633

Community-based programs for safe disposal of used needles and syringes.

G E Macalino1, K W Springer, Z S Rahman, D Vlahov, T S Jones.   

Abstract

OBJECTIVES: To review issues related to discarded syringes in the community and to describe community-based programs for the safe disposal of used needles and syringes.
METHODS: We used the medical literature and chain referral to identify community-based syringe disposal programs other than syringe exchange programs (SEPs). We held a workshop in June 1996 involving staff from disposal programs; manufacturers of syringes, sharps containers, and other disposal devices; solid waste companies; public health staff; and researchers.
RESULTS: Fifteen programs for the safe disposal of syringes were identified in the United States, Canada, and Australia. Of these, 12 primarily served persons with diabetes who use insulin, and 3 primarily served injection drug users (IDUs). The programs used three major strategies: puncture-resistant containers discarded in trash, community drop boxes, and sharps containers turned in for biohazard disposal at community sites, hospitals, or pharmacies. Participants in the workshop described key points in developing syringe disposal programs. Programs should involve pharmacists, physicians, waste disposal companies, public health departments, hospitals, diabetes educators, persons with diabetes who use insulin, and IDUs. For IDUs, criminal penalties for possession of syringes are a substantial deterrent to participation in community efforts to safely dispose of used syringes. The multiple and sometimes conflicting local, state, and federal laws and regulations concerning medical waste hinder development of multistate or national approaches to the safe disposal of syringes. More information is needed on community-based syringe disposal programs.
CONCLUSION: Communities in the United States, Canada, and Australia have developed different approaches to achieve safe disposal of used syringes.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9663633     DOI: 10.1097/00042560-199802001-00019

Source DB:  PubMed          Journal:  J Acquir Immune Defic Syndr Hum Retrovirol        ISSN: 1077-9450


  11 in total

1.  The effect of a needle exchange program on numbers of discarded needles: a 2-year follow-up.

Authors:  M C Doherty; B Junge; P Rathouz; R S Garfein; E Riley; D Vlahov
Journal:  Am J Public Health       Date:  2000-06       Impact factor: 9.308

2.  Increasing safe syringe collection sites in New York State.

Authors:  Susan J Klein; Alma R Candelas; Jay G Cooper; Wesley E Badillo; James M Tesoriero; Haven B Battles; Hope A Plavin
Journal:  Public Health Rep       Date:  2008 Jul-Aug       Impact factor: 2.792

Review 3.  Prevention and treatment of hepatitis C in injection drug users.

Authors:  Brian R Edlin
Journal:  Hepatology       Date:  2002-11       Impact factor: 17.425

4.  Medical injection use among adults and adolescents aged 15 to 64 years in Kenya: results from a national survey.

Authors:  Daniel Kimani; Rachel Kamau; Victor Ssempijja; Katherine Robinson; Tom Oluoch; Mercy Njeru; Jane Mwangi; David Njogu; Andrea A Kim
Journal:  J Acquir Immune Defic Syndr       Date:  2014-05-01       Impact factor: 3.731

Review 5.  Syringe availability as HIV prevention: a review of modalities.

Authors:  P Coffin
Journal:  J Urban Health       Date:  2000-09       Impact factor: 3.671

6.  Improper sharp disposal practices among diabetes patients in home care settings: Need for concern?

Authors:  Anindo Majumdar; Jayaprakash Sahoo; Gautam Roy; Sadishkumar Kamalanathan
Journal:  Indian J Endocrinol Metab       Date:  2015 May-Jun

7.  Knowledge and Self-Reported Practice of Insulin Injection Device Disposal among Diabetes Patients in Gondar Town, Ethiopia: A Cross-Sectional Study.

Authors:  Abebe Basazn Mekuria; Begashaw Melaku Gebresillassie; Daniel Asfaw Erku; Kaleab Taye Haile; Eshetie Melese Birru
Journal:  J Diabetes Res       Date:  2016-09-25       Impact factor: 4.011

8.  Return Rates for Needle Exchange Programs: A Common Criticism Answered.

Authors:  Kate Ksobiech
Journal:  Harm Reduct J       Date:  2004-04-19

9.  Syringe access for the prevention of blood borne infections among injection drug users.

Authors:  Sharon Stancliff; Bruce Agins; Josiah D Rich; Scott Burris
Journal:  BMC Public Health       Date:  2003-11-21       Impact factor: 3.295

Review 10.  Forum for Injection Technique and Therapy Expert Recommendations, India: The Indian Recommendations for Best Practice in Insulin Injection Technique, 2017.

Authors:  Nikhil Tandon; Sanjay Kalra; Yatan Pal Singh Balhara; Manash P Baruah; Manoj Chadha; Hemraj B Chandalia; K M Prasanna Kumar; S V Madhu; Ambrish Mithal; Rakesh Sahay; Rishi Shukla; Annamalai Sundaram; Ambika G Unnikrishnan; Banshi Saboo; Vandita Gupta; Subhankar Chowdhury; Jothydev Kesavadev; Subhash K Wangnoo
Journal:  Indian J Endocrinol Metab       Date:  2017 Jul-Aug
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.