Literature DB >> 9662144

Temporospatial heterogeneity of myocardial perfusion and blood volume in the porcine heart wall.

E L Ritman1.   

Abstract

Spatial heterogeneity of myocardial perfusion has been recognized for many years. Whether this is primarily the result of heterogeneity of parameters such as myocardial metabolism, of intramyocardial mechanical forces, or of vasomotor function within the myocardial microcirculation, is not clear. A practical problem is that it has been almost impossible to measure any two of these parameters simultaneously in the same piece of myocardium so that an unambiguous correlation, much less a cause-and-effect relationship, has been difficult to establish. In this study of six anesthetized pigs, we propose that whole-body computed tomography is a method for providing the simultaneous measurement of heterogeneity of myocardial perfusion (F) and myocardial blood volume (rho). The first finding was that the empirical relationship rho=AF+BF(0.5) between myocardial blood flow (F) and intramyocardial blood volume (rho) is maintained over a range of sizes of regions of interest (approximately 1 to 0.125 cm3) within the myocardium of each individual animal despite the spatial heterogeneity of the F and the rho values. The value of A ranges from 0.014 to 0.021 min and of B ranges from 0.061 to 0.076 ml(0.5) g(-0.5) min(0.5). A second finding was that the pattern of spatial heterogeneity of F and of rho remained reasonably stable over at least a 1 h period.

Entities:  

Mesh:

Year:  1998        PMID: 9662144     DOI: 10.1114/1.98

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  5 in total

1.  A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

Authors:  Juan C Ramirez-Giraldo; Lifeng Yu; Birgit Kantor; Erik L Ritman; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

Review 2.  State of the Art. A structural and functional assessment of the lung via multidetector-row computed tomography: phenotyping chronic obstructive pulmonary disease.

Authors:  Eric A Hoffman; Brett A Simon; Geoffrey McLennan
Journal:  Proc Am Thorac Soc       Date:  2006-08

Review 3.  Functional imaging: CT and MRI.

Authors:  Edwin J R van Beek; Eric A Hoffman
Journal:  Clin Chest Med       Date:  2008-03       Impact factor: 2.878

4.  Three-dimensional porous biodegradable polymeric scaffolds fabricated with biodegradable hydrogel porogens.

Authors:  Jinku Kim; Michael J Yaszemski; Lichun Lu
Journal:  Tissue Eng Part C Methods       Date:  2009-12       Impact factor: 3.056

Review 5.  Fractal analysis in radiological and nuclear medicine perfusion imaging: a systematic review.

Authors:  Florian Michallek; Marc Dewey
Journal:  Eur Radiol       Date:  2013-08-23       Impact factor: 5.315

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.