Literature DB >> 9659617

The effects of cobalt chromium upon macrophages.

S M Horowitz1, W T Luchetti, J B Gonzales, C K Ritchie.   

Abstract

The purpose of this study was to elucidate the mechanisms by which cobalt chromium particulate wear debris contribute to the aseptic loosening of total joint prostheses. Incubation of macrophages with cobalt chromium led to release of tumor necrosis factor-alpha (TNF-alpha) and prostaglandin E2 (PGE2), but did not lead to release of interleukin-1 beta (IL-1 beta) or interleukin 6 (IL-6). Exposure of macrophages cocultured with osteoblasts to cobalt chromium also led to significant release of TNF-alpha and PGE2, but did not lead to significant IL-6 or IL-1 beta production. The release of PGE2 in the coculture system was greater than that detected when macrophages were exposed to cobalt chromium without the osteoblast contribution. Exposure of radiolabeled calvaria to media from macrophages incubated with cobalt chromium in coculture with osteoblasts led to release of 45Ca. In contrast, exposure of radiolabeled calvaria to media from isolated macrophages incubated with these particles did not result in release of 45Ca. Exposure of macrophages to cobalt chromium was toxic, as reflected by release of the intracellular enzyme lactate dehydrogenase. Macrophages play a role in the initiation of bone resorption at the interface through the phagocytosis of cobalt chromium particles and subsequent release of TNF-alpha and PGE2. The presence of osteoblasts at the interface may be required for amplification of the inflammatory response and ultimately for bone resorption.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9659617     DOI: 10.1002/(sici)1097-4636(19980905)41:3<468::aid-jbm17>3.0.co;2-e

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  4 in total

1.  Phenotypic characteristics of T lymphocytes in the interfacial tissue of aseptically loosened prosthetic joints.

Authors:  B Hercus; P A Revell
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

2.  Release of elements from retrieved maxillofacial plates and screws.

Authors:  C Bertoldi; J M Pradelli; U Consolo; D Zaffe
Journal:  J Mater Sci Mater Med       Date:  2005-09       Impact factor: 3.896

3.  Serum levels of interleukin 6 (IL-6), granulocyte-macrophage colony-stimulating factor (GM-CSF) and elastase in aseptic prosthetic loosening.

Authors:  Nikolaus A Streich; Steffen J Breusch; Ulrich Schneider
Journal:  Int Orthop       Date:  2003-07-15       Impact factor: 3.075

4.  The pathobiology and pathology of aseptic implant failure.

Authors:  N A Athanasou
Journal:  Bone Joint Res       Date:  2016-05       Impact factor: 5.853

  4 in total