Literature DB >> 9659132

Comparison of the precision of two vertebral morphometry programs for the lunar EXPERT-XL imaging densitometer.

S B Harvey1, K M Hutchison, E C Rennie, D W Hukins, D M Reid.   

Abstract

Comparative precision tests of the vertebral height measurement function of the Aberdeen Vertebral Morphometry System (AVMS) software and Lunar EXPERT-XL software were undertaken using four vertebrae from the same lateral spine dual energy X-ray absorptiometry (DXA) image of the same subject (male, 67 years). Two of the vertebrae were abnormal and two were normal. Three observers inexperienced in morphometry and one experienced observer took part in the study. Repeatability was obtained from 10 sequential measurements of the posterior, middle and anterior heights at the same sitting by the same observer. Intraobserver reproducibility compared the means of one set of measurements for all vertebrae with another taken 1 week later. Interobserver reproducibility compared the means of one set of measurements for all vertebrae from an experienced and an inexperienced observer, and from two inexperienced observers. The AVMS software had significantly higher (p < 0.05) repeatability (mean coefficient of variability, CV = 3.5%) than the Lunar software (mean CV = 5%), significantly higher (p < 0.01) intraobserver reproducibility (mean CV = 4.6%) than the Lunar software (mean CV = 8.5%), and significantly higher (p < 0.05) interobserver reproducibility (mean CV = 4.7%) than the Lunar software (mean CV = 7.5%). In conclusion, the new AVMS method possessed higher precision when measuring both abnormal and normal vertebrae and when used by both experienced and inexperienced observers.

Mesh:

Year:  1998        PMID: 9659132     DOI: 10.1259/bjr.71.844.9659132

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  3 in total

1.  Vertebral morphometry reference data by X-ray absorptiometry (MXA) in Iranian women.

Authors:  A Salimzadeh; M Moghaddassi; G H Alishiri; M B Owlia; L Kohan
Journal:  Clin Rheumatol       Date:  2006-08-29       Impact factor: 2.980

2.  Incidence of vertebral deformities in 255 female rheumatoid arthritis patients measured by morphometric X-ray absorptiometry.

Authors:  Ragnhild E Orstavik; Glenn Haugeberg; Till Uhlig; Petter Mowinckel; Jan A Falch; Johan I Halse; Tore K Kvien
Journal:  Osteoporos Int       Date:  2004-06-12       Impact factor: 4.507

Review 3.  Vertebral morphometry: current methods and recent advances.

Authors:  G Guglielmi; D Diacinti; C van Kuijk; F Aparisi; C Krestan; J E Adams; T M Link
Journal:  Eur Radiol       Date:  2008-03-20       Impact factor: 7.034

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.