Literature DB >> 9657456

Validation of predicted total body water and extracellular water by multi-frequency impedance in young Indonesian adults.

M Bartz1, J Küpper, W Schultink, W Lukito, P Deurenberg.   

Abstract

To investigate the validity of the prediction of body water compartments by multi-frequency impedance in Indonesians, 42 adults (19 males and 23 females) were recruited in Jakarta, the capital of Indonesia. Extracellular water (ECW) and total body water (TBW) were measured with dilution techniques and predicted from body impedance at 1 and 100 kHz, respectively, using prediction formulas developed in a Dutch population. Furthermore, body weight, body height and body density were measured and as a measure of body build TBW/height and ECW/height were calculated. Percent ECW of body weight in both males (26 +/- 3%) and females (23 +/- 2%) was higher compared to the Dutch reference population, and also the body water distribution (ECW/TBW) was higher (0.46 +/- 0.04) compared to the reference population. TBW/height and ECW/height appeared to be considerably lower in the Indonesian group compared to the reference group, indicating a more slender body shape. TBW was overestimated by 1.8 +/- 2.4 and 2.5 +/- 1.3 kg in males and females, respectively. ECW was underestimated in males by 0.1 +/- 1.2 kg and slightly overestimated in females (0.1 +/- 1.0 kg). After corrections for differences in body build and body water distribution the bias of the predicted TBW was markedly reduced from 2.2 +/- 1.9 to 1.3 +/- 1.8 kg (males and females combined). For ECW the bias after correction for body water distribution and body build was 0.3 +/- 0.6 kg (males and females combined). It is concluded that multi-frequency impedance is suitable for the prediction of body water compartments at the population level but, due to differences in body build and body water distribution, validation in a larger group of Indonesian subjects is needed to avoid systematic prediction errors.

Entities:  

Mesh:

Year:  1998        PMID: 9657456     DOI: 10.1159/000012725

Source DB:  PubMed          Journal:  Ann Nutr Metab        ISSN: 0250-6807            Impact factor:   3.374


  3 in total

1.  Proposal of new body composition prediction equations from bioelectrical impedance for Indonesian men.

Authors:  J Hastuti; M Kagawa; N M Byrne; A P Hills
Journal:  Eur J Clin Nutr       Date:  2016-06-29       Impact factor: 4.016

2.  Rapid measurement of total body water to facilitate clinical decision making in hospitalized elderly patients.

Authors:  James S Powers; Leena Choi; Rhonda Bitting; Nitin Gupta; Maciej Buchowski
Journal:  J Gerontol A Biol Sci Med Sci       Date:  2009-02-19       Impact factor: 6.053

3.  Hypervolemia for hypertension pathophysiology: a population-based study.

Authors:  Ender Hür; Melih Özişik; Cihan Ural; Gürsel Yildiz; Kemal Mağden; Sennur Budak Köse; Füruzan Köktürk; Çağatay Büyükuysal; Ibrahim Yildirim; Gültekin Süleymanlar; Kenan Ateş; Soner Duman
Journal:  Biomed Res Int       Date:  2014-08-11       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.