Literature DB >> 9657195

Hemodynamic changes in arterial feeders and draining veins during embolotherapy of arteriovenous malformations: an experimental study in a swine model.

Y Murayama1, T F Massoud, F Viñuela.   

Abstract

OBJECTIVE: Transcatheter assessment of changes in draining vein (DV) flow velocity has been proposed recently as a potentially useful procedure for hemodynamic monitoring of the progression of embolotherapy in cerebral arteriovenous malformations (AVMs). We compared and contrasted changes in hemodynamic parameters of arterial feeders (AFs) and DVs during experimental AVM embolotherapy.
METHODS: Carotid-jugular fistula-type AVM models were surgically created in eight swine. Pre- and postembolization transcatheter mean AF and DV pressures, DV-time average spectral peak velocity, and AF and DV pulsatility indices were assessed. An expression, the peak systolic velocity minus end-diastolic velocity (Vs - Ved), was also used in evaluating the transvenous Doppler spectra. Pre- and postembolization hemodynamic parameters were compared statistically.
RESULTS: Pre-embolization DV flow was pulsatile (Vs - Ved, 12 +/- 4.8 cm/s), with a mean DV velocity of 39.3 +/- 11.4 cm per second. Postembolization, this changed to a less/nonpulsatile pattern (Vs - Ved, 5.4 +/- 2.7 cm/s; P = 0.0035) with a lower mean DV-average spectral peak velocity of 7.0 +/- 3.1 cm per second (P = 0.0001). The mean DV pressure was also reduced from 52.0 +/- 8.2 to 45.5 +/- 8.7 mm Hg (P = 0.0023). The mean AF pressure increased from a mean of 79.5 +/- 15.5 to 96.8 +/- 16.2 mm Hg (P = 0.0004). The DV pulsatility index values also increased from a mean of 0.3 +/- 0.2 to 1.1 +/- 0.5 (P = 0.0003). Periembolization objective hemodynamic changes were detected in the DVs earlier than were the visually subjective angiographic changes observed within the nidus.
CONCLUSION: This preliminary study indicates that transvenous assessment of average spectral peak velocity and wave pattern (Vs - Ved) may be useful in the hemodynamic evaluation of AVM shunting. The convergence of these two parameters to a range less than 10 cm per second after nidus embolization may afford a theoretical advantage over AF pressure measurements when used for objective and quantitative monitoring of endovascular embolotherapy.

Entities:  

Mesh:

Year:  1998        PMID: 9657195     DOI: 10.1097/00006123-199807000-00064

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  11 in total

1.  Experimental arteriovenous malformations modeling in laboratory sheep versus swine.

Authors:  T F Massoud
Journal:  AJNR Am J Neuroradiol       Date:  2000-05       Impact factor: 3.825

2.  Histopathologic characteristics of a chronic arteriovenous malformation in a swine model: preliminary study.

Authors:  T F Massoud; H V Vinters; K H Chao; F Viñuela; R Jahan
Journal:  AJNR Am J Neuroradiol       Date:  2000-08       Impact factor: 3.825

3.  Endovascular Pressure Measurements: Validation with a Pulsatile Flow Model and Haemodynamic Assessment of Brain AVMs.

Authors:  M Forjaz Secca; P Vilela; J L Ferreira; F C Lopes; A Goulão
Journal:  Interv Neuroradiol       Date:  2005-02-08       Impact factor: 1.610

Review 4.  Normal perfusion pressure breakthrough phenomenon: experimental models.

Authors:  Raquel Gutiérrez-González; Alvaro Pérez-Zamarron; Gregorio Rodríguez-Boto
Journal:  Neurosurg Rev       Date:  2014-04-29       Impact factor: 3.042

5.  Europium fluorescence to visualize N-butyl 2-cyanoacrylate in embolized vessels of an arteriovenous malformation swine model.

Authors:  W J Calvo; B B Lieber; L N Hopkins; A K Wakhloo
Journal:  AJNR Am J Neuroradiol       Date:  2001-04       Impact factor: 3.825

6.  Therapeutic management of cerebral arteriovenous malformations. Present role of interventional neuroradiology.

Authors:  F Viñuela; G Duckwiler; R Jahan; Y Murayama
Journal:  Interv Neuroradiol       Date:  2005-10-27       Impact factor: 1.610

7.  Modification of a previously described arteriovenous malformation model in the swine: endovascular and combined surgical/endovascular construction and hemodynamics.

Authors:  R Siekmann; A K Wakhloo; B B Lieber; M J Gounis; A A Divani; L N Hopkins
Journal:  AJNR Am J Neuroradiol       Date:  2000-10       Impact factor: 3.825

8.  Pressure measurements in arterial feeders of brain arteriovenous malformations before and after endovascular embolization.

Authors:  H Henkes; T F Gotwald; S Brew; F Kaemmerer; E Miloslavski; D Kuehne
Journal:  Neuroradiology       Date:  2004-06-15       Impact factor: 2.804

Review 9.  Brain arteriovenous malformation modeling, pathogenesis, and novel therapeutic targets.

Authors:  Wanqiu Chen; Eun-Jung Choi; Cameron M McDougall; Hua Su
Journal:  Transl Stroke Res       Date:  2014-04-12       Impact factor: 6.829

Review 10.  Development of a cerebral microvascular dysplasia model in rodents.

Authors:  H Su; Q Hao; F Shen; Y Zhu; C Z Lee; W L Young; G Y Yang
Journal:  Acta Neurochir Suppl       Date:  2008
View more