Literature DB >> 9656927

Effect of various infection-control methods for light-cure units on the cure of composite resins.

S L Chong1, Y K Lam, F K Lee, L Ramalingam, A C Yeo, C C Lim.   

Abstract

This study (1) compared the curing-light intensity with various barrier infection-control methods used to prevent cross contamination, (2) compared the Knoop hardness value of cured composite resin when various barrier control methods were used, and (3) correlated the hardness of the composite resin with the light-intensity output when different infection-control methods were used. The light-cure unit tips were covered with barriers, such as cellophane wrap, plastic gloves, Steri-shields, and finger cots. The control group had no barrier. Composite resins were then cured for each of the five groups, and their Knoop hardness values recorded. The results showed that there was significant statistical difference in the light-intensity output among the five groups. However, there was no significant statistical difference in the Knoop hardness values among any of the groups. There was also no correlation between the Knoop hardness value of the composite resin with the light-intensity output and the different infection-control methods. Therefore, any of the five infection-control methods could be used as barriers for preventing cross-contamination of the light-cure unit tip, for the light-intensity output for all five groups exceeded the recommended value of 300 W/m2. However, to allow a greater margin of error in clinical situations, the authors recommend that the plastic glove or the cellophane wrap be used to wrap the light-cure tip, since these barriers allowed the highest light-intensity output.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9656927

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  5 in total

1.  Distance and protective barrier effects on the composite resin degree of conversion.

Authors:  Margareth Coutinho; Natália Carvalho Trevizam; Renata Nakase Takayassu; Ariene Arcas Leme; Giulliana Panfiglio Soares
Journal:  Contemp Clin Dent       Date:  2013-04

2.  Effect of a multi-layer infection control barrier on the micro-hardness of a composite resin.

Authors:  In-Nam Hwang; Sung-Ok Hong; Bin-Na Lee; Yun-Chan Hwang; Won-Mann Oh; Hoon-Sang Chang
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

3.  Evaluation of effect of different disposable infection control barriers on light intensity of light-curing unit and microhardness of composite - An in vitro study.

Authors:  Rajiv Tarachand Khode; Pratima Ramakrishna Shenoi; Rajesh R Kubde; Chetana S Makade; Kanchan D Wadekar; Priyanka Tarachand Khode
Journal:  J Conserv Dent       Date:  2017 May-Jun

4.  Infection Control Barrier and Curing Time as Factors Affecting the Irradiance of Light-Cure Units.

Authors:  Reem A Ajaj; Hani M Nassar; Fatin A Hasanain
Journal:  J Int Soc Prev Community Dent       Date:  2018-11-29

5.  Effect of infection control barriers on the light output from a multi-peak light curing unit.

Authors:  Carlos José Soares; Stella Sueli Lourenço Braga; Maria Tereza Hordones Ribeiro; Richard Bengt Price
Journal:  J Dent       Date:  2020-10-19       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.