Literature DB >> 9656895

The reproducibility of muscle and joint tenderness detection methods and maximum mandibular movement measurement for the temporomandibular system.

J P Goulet1, G T Clark, V F Flack, C Liu.   

Abstract

The purpose of this study was (1) to evaluate the reproducibility of two masticatory muscle and joint tenderness detection methods; (2) to evaluate the reproducibility of maximum mandibular movement measurements; and (3) to investigate factors influencing examiner agreement. The tenderness assessment procedures involved application of a standard pressure for 2 seconds over four anatomically defined masticatory muscle sites, one control forehead site, and two temporomandibular joint sites on each side of the face. One technique utilized a pressure algometer (PAP), while the other technique required that a trained examiner apply pressure with the index fingertip (FPP). Seventy-two subjects (36 patients and 36 controls) were evaluated in a single-blind study design. Control subjects were matched for age, gender, and race with temporomandibular disorder subjects. Each subject was examined twice with each of the described methods in a randomized, fully balanced sequence by calibrated examiners. Tenderness levels were determined by the subject via self-report of pain upon pressure using a standard set of verbal descriptors. Maximum pain-free, active, and passive opening, and maximum active right and left lateral movements were measured using a millimeter ruler. Intraclass correlation coefficients (ICC) for the tenderness assessment methods ranged from 0.220 to 0.739 for the FPP method and from 0.391 to 0.880 for the PAP method. ICCs for mandibular movement measurement were much less variable, ranging from 0.59 to 0.68 for lateral movement and from 0.78 to 0.93 for opening movement. These results indicate good to excellent agreement between calibrated examiners for mandibular movement measurement and for tenderness assessment methods at two masseter (i.e., superficial and deep) and the anterior temporalis sites. Only fair agreement was found for the middle temporalis and lateral TMJ capsule sites using these methods.

Entities:  

Mesh:

Year:  1998        PMID: 9656895

Source DB:  PubMed          Journal:  J Orofac Pain        ISSN: 1064-6655


  8 in total

1.  The Research Diagnostic Criteria For Temporomandibular Disorders. II: reliability of Axis I diagnoses and selected clinical measures.

Authors:  John O Look; Mike T John; Feng Tai; Kimberly H Huggins; Patricia A Lenton; Edmond L Truelove; Richard Ohrbach; Gary C Anderson; Eric L Shiffman
Journal:  J Orofac Pain       Date:  2010

2.  Cervicothoracic junction thrust manipulation in the multimodal management of a patient with temporomandibular disorder.

Authors:  Dhinu J Jayaseelan; Nancy S Tow
Journal:  J Man Manip Ther       Date:  2016-05

Review 3.  Central sensitization in fibromyalgia and other musculoskeletal disorders.

Authors:  Lars Arendt-Nielsen; Thomas Graven-Nielsen
Journal:  Curr Pain Headache Rep       Date:  2003-10

4.  Assessing the mobility of the mandibular condyle by sonography.

Authors:  Han-Yu Chen; Shyi-Kuen Wu; Chuan-Chin Lu; Jia-Yuan You; Chung-Liang Lai
Journal:  Patient Prefer Adherence       Date:  2014-10-15       Impact factor: 2.711

5.  Case-control study of craniomandibular disorders in patients with fibromyalgia.

Authors:  Eduardo-José García-Moya; José-María Montiel-Company; José-Manuel Almerich-Silla
Journal:  J Clin Exp Dent       Date:  2015-04-01

6.  Intra-rater and Inter-rater Reliability of Mandibular Range of Motion Measures Considering a Neutral Craniocervical Position.

Authors:  Hector Beltran-Alacreu; Ibai López-de-Uralde-Villanueva; Alba Paris-Alemany; Santiago Angulo-Díaz-Parreño; Roy La Touche
Journal:  J Phys Ther Sci       Date:  2014-06-30

7.  DC/TMD Examiner Protocol: Longitudinal Evaluation on Interexaminer Reliability.

Authors:  Marit Slåttelid Skeie; Paula Frid; Manal Mustafa; Jörg Aßmus; Annika Rosén
Journal:  Pain Res Manag       Date:  2018-09-26       Impact factor: 3.037

8.  The Immediate Effect of Therapeutic Touch and Deep Touch Pressure on Range of Motion, Interoceptive Accuracy and Heart Rate Variability: A Randomized Controlled Trial With Moderation Analysis.

Authors:  Darren J Edwards; Hayley Young; Ross Johnston
Journal:  Front Integr Neurosci       Date:  2018-09-21
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.