Validation of F-Scan pressure sensor system: a technical note.

Z P Luo1, L J Berglund, K N An.   

Abstract

This study performed a quantitative validation on a recently developed pressure sensitive transducer system, the F-Scan sensor system. The results indicate that the sensor is adequate for determination of pressure distribution under contact conditions with soft materials. The linear response of the sensor was up to 1.7 MPa with good homogeneity throughout sensor cells. However, the sensor is sensitive to surface conditions, loading speeds, and temperature. Variations also exist from sensor to sensor. In order to have accurate measurement, calibration was recommended in actual clinical or experimental conditions prior to use, including surface contact conditions, loading speeds, and temperature environment. In addition, this sensor system is not suitable for hard surface contact such as plexiglas.

Mesh:

Year:  1998        PMID: 9651890

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  20 in total

1.  Estimating Ground Reaction Force and Center of Pressure Using Low-Cost Wearable Devices.

Authors:  Brandon Oubre; Spencer Lane; Skylar Holmes; Katherine Boyer; Sunghoon Ivan Lee
Journal:  IEEE Trans Biomed Eng       Date:  2022-03-18       Impact factor: 4.538

2.  Measuring seating pressure, area, and asymmetry in persons with spinal cord injury.

Authors:  Elena M Gutierrez; Marie Alm; Claes Hultling; Helena Saraste
Journal:  Eur Spine J       Date:  2003-11-25       Impact factor: 3.134

3.  Foot plantar pressure measurement system: a review.

Authors:  Abdul Hadi Abdul Razak; Aladin Zayegh; Rezaul K Begg; Yufridin Wahab
Journal:  Sensors (Basel)       Date:  2012-07-23       Impact factor: 3.576

4.  The impact of increasing body mass on peak and mean plantar pressure in asymptomatic adult subjects during walking.

Authors:  John B Arnold; Ryan Causby; Grad Dip Pod; Sara Jones
Journal:  Diabet Foot Ankle       Date:  2010-11-09

5.  Dressing plantar wounds with foam dressings, is it too much pressure?

Authors:  Ryan Scott Causby; M Pod; Sara Jones
Journal:  Diabet Foot Ankle       Date:  2011-11-04

6.  A Portable Gait Asymmetry Rehabilitation System for Individuals with Stroke Using a Vibrotactile Feedback.

Authors:  Muhammad Raheel Afzal; Min-Kyun Oh; Chang-Hee Lee; Young Sook Park; Jungwon Yoon
Journal:  Biomed Res Int       Date:  2015-06-16       Impact factor: 3.411

7.  No evidence for shedding of circulating tumor cells to the peripheral venous blood as a result of mammographic breast compression.

Authors:  Daniel Förnvik; Ingvar Andersson; Magnus Dustler; Roy Ehrnström; Lisa Rydén; Anders Tingberg; Sophia Zackrisson; Kristina Aaltonen
Journal:  Breast Cancer Res Treat       Date:  2013-08-29       Impact factor: 4.872

8.  A wireless flexible sensorized insole for gait analysis.

Authors:  Simona Crea; Marco Donati; Stefano Marco Maria De Rossi; Calogero Maria Oddo; Nicola Vitiello
Journal:  Sensors (Basel)       Date:  2014-01-09       Impact factor: 3.576

9.  The effect of low-dye taping on rearfoot motion and plantar pressure during the stance phase of gait.

Authors:  Kieran O'Sullivan; Norelee Kennedy; Emer O'Neill; Una Ni Mhainin
Journal:  BMC Musculoskelet Disord       Date:  2008-08-18       Impact factor: 2.362

Review 10.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.