Liquid ionization chambers for absorbed dose measurements in water at low dose rates and intermediate photon energies.

G Wickman1, B Johansson, J Bahar-Gogani, T Holmström, J E Grindborg.   

Abstract

Two new liquid ionization chamber (LIC) designs, consisting of cylindrical and plane-parallel configurations, are presented. They are designed to be suitable for high-precision measurements of absorbed dose-to-water at dose rates and photon energies typical for LDR intermediate photon energy brachytherapy sources. The chambers have a sensitive liquid layer thickness of 1 mm and sensitive volumes of 7 mm3 (plane-parallel) and 20 mm3 (cylindrical). The liquids used as sensitive media in the chambers are either isooctane (C8H18), tetramethylsilane (Si(CH3)4) or mixtures of these two liquids in the approximate proportions 2 to 1. A chamber filled with such a liquid mixture and with a polarizing voltage of 300 V, provides a volume sensitivity of about 10(-9)C Gy(-1) mm(-3) for absorbed dose measurements in water in an x-ray radiation field with an effective photon energy of 120 keV. In the interval 30 to 140 keV, the relative change in sensitivity is less than +/- 2.5%. The leakage current of the chambers is low and stable, which implies that absorbed dose measurements can be done with good reproducibility at dose-rates as low as 50 microGy min-1 (sigma < 3%). The long-term calibration stability was tested for a set of five chambers over a period of more than 1 year. No systematic change in their sensitivity could be observed. The general recombination at a polarizing voltage of 300 V is less than 2% for dose-rates up to about 100 mGy min-1. The temperature dependence at room temperature is 0.5% per degree C. The response is almost independent of the direction of the radiation for the plane-parallel LIC.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9650180     DOI: 10.1118/1.598268

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

Review 1.  Air kerma and absorbed dose standards for reference dosimetry in brachytherapy.

Authors:  T Sander
Journal:  Br J Radiol       Date:  2014-07-07       Impact factor: 3.039

2.  General ion recombination effect in a liquid ionization chamber in high-dose-rate pulsed photon and electron beams.

Authors:  Hideyuki Takei; Tomonori Isobe; Nozomi Kitamura; Yutaro Mori; Tetsuya Tomita; Daisuke Kobayashi; Satoshi Kamizawa; Tomoharu Sato; Hideyuki Sakurai; Takeji Sakae
Journal:  J Radiat Res       Date:  2018-05-01       Impact factor: 2.724

3.  Applying three different methods of measuring CTDIfree air to the extended CTDI formalism for wide-beam scanners (IEC 60601-2-44): A comparative study.

Authors:  Robert Bujila; Love Kull; Mats Danielsson; Jonas Andersson
Journal:  J Appl Clin Med Phys       Date:  2018-06-14       Impact factor: 2.102