Literature DB >> 9649173

Distortion behavior of heat-activated acrylic denture-base resin in conventional and long, low-temperature processing methods.

M Kawara1, O Komiyama, S Kimoto, N Kobayashi, K Kobayashi, K Nemoto.   

Abstract

There have been many reports on fatal distortion of heat-activated acrylic denture-base resin which is still widely used in the field of removable prosthodontics. However, these reports have failed to report quantitatively on polymerization and thermal shrinkage factors. In the present study, we attempted to verify that the shrinkage of heat-activated acrylic denture-base resin was caused mainly by thermal contraction after processing. Furthermore, we examined the degree of distortion resulting from long, low-temperature processing, and compared the results with that of the conventional method. The strain gauge and thermo-couple were embedded in a specimen at the time of resin packing. The measurement started from the beginning of processing and continued until the specimen was bench-cooled and immediately before and after it was de-flasked, as well as during seven-day immersion in water at 37 degrees C. The resin expanded when processed by the conventional method. Meanwhile, mild shrinkage, possibly polymerization shrinkage, was observed when the resin was processed by the low-temperature method. This suggested that polymerization shrinkage was compensated for by thermal expansion during processing by the conventional method. Moreover, the shrinkage strains in the period from the completion of processing to immediately after de-flasking, in both the conventional and low-temperature methods, were identical to the theoretical value of thermal shrinkage which we obtained by multiplying the linear coefficients of thermal expansion by temperature differences. The shrinkage strain in the specimen processed by the low-temperature method, measured from the end of processing to immediately after de-flasking, averaged 64% of that in the specimen processed by the conventional method. The results revealed quantitatively that the shrinkage of heat-activated acrylic denture-base resin was mainly thermal shrinkage, and demonstrated the advantage of the low-temperature method in reducing thermal shrinkage.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9649173     DOI: 10.1177/00220345980770060901

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  7 in total

1.  Teeth movement in denture and implant-supported prosthesis influenced by microwave flask systems.

Authors:  Rafael L X Consani; Leonardo G Sonehara; Marcelo F Mesquita; Valentim A R Barão; Conrado R Caetano
Journal:  J Oral Biol Craniofac Res       Date:  2015-07-15

2.  Novel Cold Cure Acrylic Denture Base with Recycled Zirconia Nano-Fillers That Were Functionalized by HEMA Agent Incorporation: Using the Sprinkle Approach.

Authors:  Hala B Elzahar; Mohamed S El-Okaily; Mohamed H Khedr; Mohamed Amgad Kaddah; Ahmed A G El-Shahawy
Journal:  Int J Nanomedicine       Date:  2022-09-29

Review 3.  Mechanical Properties of the Modified Denture Base Materials and Polymerization Methods: A Systematic Review.

Authors:  Aftab Ahmed Khan; Muhammad Amber Fareed; Abdulkarim Hussain Alshehri; Alhanoof Aldegheishem; Rasha Alharthi; Selma A Saadaldin; Muhammad Sohail Zafar
Journal:  Int J Mol Sci       Date:  2022-05-20       Impact factor: 6.208

4.  Effect of different palatal vault shapes on the dimensional stability of glass fiber-reinforced heat-polymerized acrylic resin denture base material.

Authors:  Mehmet Dalkiz; Demet Arslan; Ali Riza Tuncdemir; M Selim Bilgin; Halil Aykul
Journal:  Eur J Dent       Date:  2012-01

5.  Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method.

Authors:  Suji Lee; Seoung-Jin Hong; Janghyun Paek; Ahran Pae; Kung-Rock Kwon; Kwantae Noh
Journal:  J Adv Prosthodont       Date:  2019-02-26       Impact factor: 1.904

Review 6.  Flexural Strength of CAD/CAM Denture Base Materials: Systematic Review and Meta-analysis of In-vitro Studies.

Authors:  Reem Abualsaud; Mohammed M Gad
Journal:  J Int Soc Prev Community Dent       Date:  2022-04-08

7.  Effect of flask closure method and post-pressing time on the displacement of maxillary denture teeth.

Authors:  Wagner A Negreiros; Rafael L X Consani; Marcelo F Mesquita; Mario A C Sinhoreti; Ivan R Faria
Journal:  Open Dent J       Date:  2009-03-06
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.