Literature DB >> 9646809

Coronary artery stenoses: assessment with contrast-enhanced electron-beam CT and axial reconstructions.

G P Reddy1, D M Chernoff, J R Adams, C B Higgins.   

Abstract

PURPOSE: To evaluate the usefulness of electron-beam computed tomography (CT) for identification of coronary artery stenoses.
MATERIALS AND METHODS: Coronary angiography and contrast material-enhanced, electrocardiographically triggered electron-beam CT of the heart were performed in 23 patients. With axial CT images and axial maximum intensity projection reconstructions, the coronary arteries were assessed by two observers blinded to the results of angiography.
RESULTS: Cardiac motion artifact (unsharpness) precluded evaluation of the right coronary artery (RCA) in six subjects and the left circumflex coronary artery (LCX) in one patient. With the vessels degraded by motion artifact eliminated from analysis, overall sensitivity of electron-beam CT for hemodynamically significant stenoses was 88%, and specificity was 79%. In the left anterior descending coronary artery (LAD), sensitivity was 93% and specificity was 63%; in the LCX, sensitivity was 100% and specificity was 67%; and in the RCA, sensitivity was 67% and specificity was 77%. The presence of coronary artery calcification did not have an effect on sensitivity for stenoses, but it did decrease specificity.
CONCLUSION: Electron-beam CT angiography can depict hemodynamically significant stenoses in the LAD and LCX with a sensitivity of more than 90%. The presence of coronary artery calcification resulted in decreased specificity but no appreciable change in sensitivity.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9646809     DOI: 10.1148/radiology.208.1.9646809

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

Review 1.  Recent advances: diagnostic radiology.

Authors:  J Hawnaur
Journal:  BMJ       Date:  1999-07-17

2.  Non-invasive coronary imaging: computed tomography or magnetic resonance imaging?

Authors:  C R Peebles
Journal:  Heart       Date:  2003-06       Impact factor: 5.994

3.  Congenital anomalies of the coronary arteries: imaging with contrast-enhanced, multidetector computed tomography.

Authors:  Rainer Schmitt; Steffen Froehner; Juergen Brunn; Matthias Wagner; Horst Brunner; Oleg Cherevatyy; Frank Gietzen; Georgios Christopoulos; Sebastian Kerber; Franz Fellner
Journal:  Eur Radiol       Date:  2005-03-09       Impact factor: 5.315

4.  Evaluation of the coronary venous system using electron beam computed tomography.

Authors:  T C Gerber; P F Sheedy; M R Bell; D L Hayes; J A Rumberger; T Behrenbeck; D R Holmes; R S Schwartz
Journal:  Int J Cardiovasc Imaging       Date:  2001-02       Impact factor: 2.357

5.  Contrast enhanced electron beam computed tomography to analyse the coronary arteries in patients after acute myocardial infarction.

Authors:  S Achenbach; D Ropers; M Regenfus; G Muschiol; W G Daniel; W Moshage
Journal:  Heart       Date:  2000-11       Impact factor: 5.994

Review 6.  Imaging of coronary atherosclerosis and identification of the vulnerable plaque.

Authors:  P J de Feyter; P W Serruys; K Nieman; N Mollet; F Cademartiri; R J van Geuns; C Slager; A F W van der Steen; R Krams; J A Schaar; P Wielopolski; P M T Pattynama; A Arampatzis; A van der Lugt; E Regar; J Ligthart; P Smits
Journal:  Neth Heart J       Date:  2003-09       Impact factor: 2.380

Review 7.  Non-invasive coronary angiography with multi-detector computed tomography: comparison to conventional X-ray angiography.

Authors:  Paul Schoenhagen; Arthur E Stillman; Sandy S Halliburton; Stacie A Kuzmiak; Tracy Painter; Richard D White
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

8.  Defining the optimal systolic phase targets using absolute delay time for reconstructions in dual-source coronary CT angiography.

Authors:  Csilla Celeng; Harshna Vadvala; Stefan Puchner; Amit Pursnani; Umesh Sharma; Attila Kovacs; Pâl Maurovich-Horvat; Udo Hoffmann; Brian Ghoshhajra
Journal:  Int J Cardiovasc Imaging       Date:  2015-09-03       Impact factor: 2.357

9.  Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography.

Authors:  A W Leber; A Knez; C Becker; A Becker; C White; C Thilo; M Reiser; R Haberl; G Steinbeck
Journal:  Heart       Date:  2003-06       Impact factor: 5.994

10.  The utility of multi-detector row spiral CT for detection of coronary artery stenoses.

Authors:  Jae-Youn Moon; Namsik Chung; Byoung Wook Choi; Kyu Ok Choe; Hye Sun Seo; Young-Guk Ko; Seok-Min Kang; Jong-Won Ha; Se-Joong Rim; Yangsoo Jang; Won-Heum Shim; Seung-Yun Cho
Journal:  Yonsei Med J       Date:  2005-02-28       Impact factor: 2.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.