Literature DB >> 9646442

Aujeszky's disease (pseudorabies) virus detection in cerebrospinal fluid in experimentally infected pigs.

M Balasch1, J Pujols, J Segalés, M Pumarola.   

Abstract

The presence of Aujeszky's disease virus in cerebrospinal fluid of experimentally infected pigs was studied using the techniques of virus isolation and PCR. Pigs, some of which were previously vaccinated against Aujeszky's disease, were inoculated with different doses of the Aujeszky's disease NIA-3 strain. At the time of death or sacrifice, a sample of cerebrospinal fluid was taken and tested for the presence of virus using the mentioned techniques. Virus was isolated only from one sample, while it was detected by PCR in most of them. The higher sensitivity of the PCR technique and the possible presence of antiviral antibodies in the cerebrospinal fluid are reasons that can be argued to explain this fact. By PCR, the virus was detected more efficiently when digested cerebrospinal fluid cells were used as DNA source than when using whole cerebrospinal fluid, suggesting that the virus could be cell-associated. Aujeszky's disease virus could not be detected by PCR in pigs which survived the acute phase of the infection and were euthanased at 8 weeks post-inoculation, when they were latently infected. This indicated that the cerebrospinal fluid is not an adequate sample for the diagnosis of latency. Since Aujeszky's disease virus was detected from most of the tested samples, we believe that this could be an adequate procedure for the quick diagnosis of Aujeszky's disease.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9646442     DOI: 10.1016/s0378-1135(97)00156-9

Source DB:  PubMed          Journal:  Vet Microbiol        ISSN: 0378-1135            Impact factor:   3.293


  4 in total

1.  Pseudorabies virus infection (Aujeszky's disease) in an Iberian lynx (Lynx pardinus) in Spain: a case report.

Authors:  A Javier Masot; María Gil; David Risco; Olga M Jiménez; José I Núñez; Eloy Redondo
Journal:  BMC Vet Res       Date:  2017-01-05       Impact factor: 2.741

2.  Loop-mediated isothermal amplification for rapid detection and differentiation of wild-type pseudorabies and gene-deleted virus vaccines.

Authors:  Chao-Fan Zhang; Shang-Jin Cui; Chao Zhu
Journal:  J Virol Methods       Date:  2010-08-04       Impact factor: 2.014

3.  Duplex fluorescence melting curve analysis as a new tool for rapid detection and differentiation of genotype I, II and Bartha-K61 vaccine strains of pseudorabies virus.

Authors:  Zhicheng Liu; Chunhong Zhang; Haiyan Shen; Junying Sun; Jianfeng Zhang
Journal:  BMC Vet Res       Date:  2018-11-28       Impact factor: 2.741

4.  Loop-mediated isothermal amplification establishment for detection of pseudorabies virus.

Authors:  Fang-Xue En; Xiong Wei; Li Jian; Chen Qin
Journal:  J Virol Methods       Date:  2008-05-12       Impact factor: 2.014

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.