Literature DB >> 9644898

Microfabricated cantilevers for measurement of subcellular and molecular forces.

M E Fauver1, D L Dunaway, D H Lilienfeld, H G Craighead, G H Pollack.   

Abstract

We present two new microfabricated cantilever-beam force transducers. The transducers were fabricated from thin silicon-nitride films, and were used respectively to measure forces generated by two small-muscle preparations: the single myofibril, and the single actin filament in contact with a myosin-coated surface. A simple resonance method was developed to characterize the transducers. Because of the high reproducibility of lever dimensions and the consistency of the modulus of elasticity, few calibration measurements sufficed to characterize the stiffness of all the levers on a single wafer.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9644898     DOI: 10.1109/10.686797

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  14 in total

1.  Direct measurement of single synthetic vertebrate thick filament elasticity using nanofabricated cantilevers.

Authors:  Dwayne Dunaway; Mark Fauver; Gerald Pollack
Journal:  Biophys J       Date:  2002-06       Impact factor: 4.033

2.  Quantal length changes in single contracting sarcomeres.

Authors:  F A Blyakhman; T Shklyar; G H Pollack
Journal:  J Muscle Res Cell Motil       Date:  1999-08       Impact factor: 2.698

3.  Mechanics of F-actin characterized with microfabricated cantilevers.

Authors:  Xiumei Liu; Gerald H Pollack
Journal:  Biophys J       Date:  2002-11       Impact factor: 4.033

4.  Effect of sarcomere length on step size in relaxed rabbit psoas muscle.

Authors:  Ekaterina Nagornyak; Felix Blyakhman; Gerald H Pollack
Journal:  J Muscle Res Cell Motil       Date:  2004       Impact factor: 2.698

5.  Passive stiffness of Drosophila IFM myofibrils: a novel, high accuracy measurement method.

Authors:  Yudong Hao; Sanford I Bernstein; Gerald H Pollack
Journal:  J Muscle Res Cell Motil       Date:  2004       Impact factor: 2.698

6.  Stepwise length changes in single invertebrate thick filaments.

Authors:  Ekaterina M Nagornyak; Felix A Blyakhman; Gerald H Pollack
Journal:  Biophys J       Date:  2005-08-19       Impact factor: 4.033

7.  History-dependent properties of skeletal muscle myofibrils contracting along the ascending limb of the force-length relationship.

Authors:  Clara Pun; Ali Syed; Dilson E Rassier
Journal:  Proc Biol Sci       Date:  2009-10-21       Impact factor: 5.349

8.  Protein kinase A changes calcium sensitivity but not crossbridge kinetics in human cardiac myofibrils.

Authors:  John S Walker; Lori A Walker; Ken Margulies; Peter Buttrick; Pieter de Tombe
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-04-15       Impact factor: 4.733

9.  The load dependence and the force-velocity relation in intact myosin filaments from skeletal and smooth muscles.

Authors:  Yu-Shu Cheng; Felipe de Souza Leite; Dilson E Rassier
Journal:  Am J Physiol Cell Physiol       Date:  2019-10-16       Impact factor: 4.249

10.  Glass microneedles for force measurements: a finite-element analysis model.

Authors:  Peter N Ayittey; John S Walker; Jeremy J Rice; Pieter P de Tombe
Journal:  Pflugers Arch       Date:  2008-12-23       Impact factor: 3.657

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.