Validation of antibody-based recognition by piezoelectric transducers through electroacoustic admittance analysis.

K Bizet1, C Gabrielli, H Perrot, J Therasse.   

Abstract

The development of immunosensors based on piezoelectric transducers is widely investigated due to their attractive potentialities. The quartz crystal microbalance (QCM) may give a direct response signal which characterizes the binding event between a sensitive layer, immobilized onto the surface transducer, and the analysis to be detected. However, for small biomolecules, such as some antigens, it is quite difficult to obtain an observable signal. This is mainly due to the lack of sensitivity of the commonly used QCM (5 to 10 MHz quartz crystal). Moreover, the mass estimated with the QCM response through the Sauerbrey equation and the mass which can be measured thanks to other analytical techniques, in our case an enzymatic assay, are different: the deposited mass is generally overestimated by the QCM. To validate QCM mass measurements and, therefore antigens recognition, the interactions of acoustic shear waves with a biolayer were investigated during enzyme adsorption onto the microbalance gold electrode or during the antibody/antigen binding. Electroacoustic admittance was measured around the resonance frequency of a 27 MHz quartz resonator in parallel with microbalance measurements. The parameters which characterize the quartz microbalance equivalent circuit were compared with the classical microbalance frequency. The mass overestimation, given by the microbalance, could be explained either by modification of the rheological properties of the sensitive layers and/or by an inadequacy of the assay performed.

Mesh:

Substances:

Year:  1998        PMID: 9642764     DOI: 10.1016/s0956-5663(97)00139-5

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Conformational change of bacteriorhodopsin quantitatively monitored by microcantilever sensors.

Authors:  Thomas Braun; Natalija Backmann; Manuel Vögtli; Alexander Bietsch; Andreas Engel; Hans-Peter Lang; Christoph Gerber; Martin Hegner
Journal:  Biophys J       Date:  2006-01-27       Impact factor: 4.033

2.  Development of a mass sensitive quartz crystal microbalance (QCM)-based DNA biosensor using a 50 MHz electronic oscillator circuit.

Authors:  Gonzalo García-Martinez; Enrique Alonso Bustabad; Hubert Perrot; Claude Gabrielli; Bogdan Bucur; Mathieu Lazerges; Daniel Rose; Loreto Rodriguez-Pardo; Jose Fariña; Chantal Compère; Antonio Arnau Vives
Journal:  Sensors (Basel)       Date:  2011-08-03       Impact factor: 3.576

3.  A Study on Increasing Sensitivity of Rectangular Microcantilevers Used in Biosensors.

Authors:  Mohd Zahid Ansari; Chongdu Cho
Journal:  Sensors (Basel)       Date:  2008-11-25       Impact factor: 3.576

4.  Quinone-based polymers for label-free and reagentless electrochemical immunosensors: application to proteins, antibodies and pesticides detection.

Authors:  Benoit Piro; Steeve Reisberg; Guillaume Anquetin; Huynh-Thien Duc; Minh-Chau Pham
Journal:  Biosensors (Basel)       Date:  2013-01-14
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.