Literature DB >> 9641419

Angle-fixated anterior chamber phakic intraocular lens for myopia of -7 to -19 diopters.

G Baikoff1, J L Arne, Y Bokobza, J Colin, J L George, F Lagoutte, P Lesure, M Montard, J J Saragoussi, P Secheyron.   

Abstract

PURPOSE: To assess the safety and efficacy of a second generation, anterior chamber phakic intraocular lens (Baikoff Model ZB5M) in patients with high myopia.
METHODS: One hundred and twenty-one patients (134 eyes) with myopia of -7.00 to -18.80 D were implanted with the ZB5M lens and followed for 18 to 52 months; the number of eyes evaluated was: 6 months (104 eyes), 1 year (91 eyes), 18 months (78 eyes), 2 years (68 eyes), and 3 years (35 eyes).
RESULTS: Postoperative spherical equivalent refraction averaged -1.00 D and the error in refractive correction (achieved minus intended) averaged -0.40 D during the first 2 years, increasing -to -1.30 D refraction and -0.60 D error in refractive correction at 3 years. At 2 years, approximately 40% of eyes had a spherical equivalent refraction within +/-0.50 D, and 65% within +/-1.00 D. The uncorrected distance visual acuity was 0.048 at baseline and 0.5 at 3 years; near visual acuity was 0.21 at baseline and approximately 0.7 over the 3 years of follow-up. Spectacle-corrected distance visual acuity at baseline was 0.54; it improved to 0.7. Near visual acuity was 0.65 at baseline and it improved to approximately 0.75. Endothelial cell counts in the central and peripheral cornea were reduced by an average 3.3% at 6 months, declining an additional 1% to 2% over the remaining follow-up period. Regression analyses indicated that most of the endothelial cell loss was due to surgery. Additional complications included halos/glare in 37 of 133 eyes (27.8%) and iris retraction with pupillary ovalization in 30 of 133 eyes (22.6%). The intraocular lens was exchanged in four of 133 eyes (3.0%) and removed in three of 133 eyes (2.3%), the latter because of halos (one eye) and a flat anterior chamber with severe inflammation (two eyes).
CONCLUSIONS: Implantation of the Baikoff ZB5M lens in the anterior chamber of phakic eyes significantly reduced high myopia and produced a stable refractive outcome over the 3 years, accompanied by marked improvement in uncorrected distance visual acuity and minimal, non-progressive damage to the corneal endothelium. Frequent complications included pupillary ovalization and halos/glare. Improvements in accuracy of IOL power calculations are needed.

Entities:  

Mesh:

Year:  1998        PMID: 9641419     DOI: 10.3928/1081-597X-19980501-12

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  12 in total

Review 1.  [Phakic intraocular lenses. Current status and limitations].

Authors:  H B Dick; M Tehrani
Journal:  Ophthalmologe       Date:  2004-03       Impact factor: 1.059

2.  AcrySof phakic angle-supported intraocular lens for the correction of high to extremely high myopia: one-year follow-up results.

Authors:  Rui-Bo Yang; Shao-Zhen Zhao
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

3.  An interesting case of implantable contact lens.

Authors:  V K Mohindra; Savio Pereira
Journal:  Med J Armed Forces India       Date:  2013-06-21

Review 4.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

5.  Anterior chamber width measurement by high-speed optical coherence tomography.

Authors:  Jason A Goldsmith; Yan Li; Maria Regina Chalita; Volker Westphal; Chetan A Patil; Andrew M Rollins; Joseph A Izatt; David Huang
Journal:  Ophthalmology       Date:  2005-02       Impact factor: 12.079

Review 6.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

7.  Correction of high myopia with different phakic anterior chamber intraocular lenses: ICARE angle-supported lens and Verisyse iris-claw lens.

Authors:  Stanislawa Gierek-Ciaciura; Ariadna Gierek-Lapinska; Krzysztof Ochalik; Ewa Mrukwa-Kominek
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-07-01       Impact factor: 3.117

8.  Artisan phakic intraocular lens for correcting high myopia.

Authors:  Tova Lifshitz; Jaime Levy; Isaac Aizenman; Itamar Klemperer; Shmuel Levinger
Journal:  Int Ophthalmol       Date:  2005-09-29       Impact factor: 2.031

Review 9.  [Scheimpflug photography for the examination of phakic intraocular lenses].

Authors:  M Baumeister
Journal:  Ophthalmologe       Date:  2014-10       Impact factor: 1.059

10.  Comparison of clear lens extraction and collamer lens implantation in high myopia.

Authors:  Ahmed M Emarah; Mostafa A El-Helw; Hazem M Yassin
Journal:  Clin Ophthalmol       Date:  2010-05-14
View more