Literature DB >> 9637151

Long-term results of the external fixation of distal radius fractures.

D A Rikli1, K Küpfer, A Bodoky.   

Abstract

OBJECTIVE: To evaluate the long-term results of external fixation of distal radius fractures.
METHODS: A retrospective follow-up study (median follow-up, 5.3 years) of 49 patients with 50 distal radius fractures treated with an external fixator was carried out. An external fixator (Minifixator, Stratec Medical, Waldenburg, Switzerland) was used. The operative procedure is described in detail. A personal evaluation including clinical and radiologic assessment of both wrists was performed.
RESULTS: The functional results, including the parameters strength, daily activities, range of motion, and presence of pain, as well as an anatomic score, the presence of osteoarthritis, the quality of reduction, and complications were recorded. Functional and anatomic results indicated excellent to good ratings in more than 80% of the cases.
CONCLUSION: The external fixator is a versatile tool in the treatment of intra-articular and extra-articular fractures of the distal radius. The rate of algodystrophy (reflex sympathetic dystrophy) was 6%, and wrist stiffness was not found in our series.

Entities:  

Mesh:

Year:  1998        PMID: 9637151     DOI: 10.1097/00005373-199806000-00007

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  8 in total

1.  Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures.

Authors:  Mert Kumbaraci; Levent Kucuk; Levent Karapinar; Cengizhan Kurt; Erhan Coskunol
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-02-16

2.  External fixation with or without supplementary intramedullary Kirschner wires in the treatment of distal radial fractures.

Authors:  Charles Lin; Jui-Sheng Sun; Sheng-Mou Hou
Journal:  Can J Surg       Date:  2004-12       Impact factor: 2.089

3.  Ulnocarpal stabilization in the management of comminuted fractures distal end radius.

Authors:  Dinesh K Gupta; Gaurav Kumar
Journal:  Indian J Orthop       Date:  2009-01       Impact factor: 1.251

4.  [Incorrect classification of extra-articular distal radius fractures by conventional X-rays. Comparison between biplanar radiologic diagnostics and CT assessment of fracture morphology].

Authors:  H C Dahlen; W M Franck; G Sabauri; M Amlang; H Zwipp
Journal:  Unfallchirurg       Date:  2004-06       Impact factor: 1.000

5.  Complications of treating distal radius fractures with external fixation: a community experience.

Authors:  John T Anderson; George L Lucas; Bruce R Buhr
Journal:  Iowa Orthop J       Date:  2004

6.  Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials.

Authors:  Qiang Fu; Lei Zhu; Peng Yang; Aimin Chen
Journal:  Indian J Orthop       Date:  2018 Nov-Dec       Impact factor: 1.251

7.  Hybrid external fixation for neglected fractures of the distal radius: results after one year.

Authors:  Paweł Grala; Wojciech Zieliński
Journal:  J Orthop Traumatol       Date:  2008-09-19

8.  Comparison of outcome of VLCP versus PKEF in the treatment of AO type C2-3 distal radial fractures.

Authors:  Zhibing Tang; Jinlian Liu; Huilin Yang
Journal:  Ann Med Surg (Lond)       Date:  2017-05-13
  8 in total