Literature DB >> 9635934

Specific airway resistance, interrupter resistance, and respiratory impedance in healthy children aged 2-7 years.

B Klug1, H Bisgaard.   

Abstract

We report data on respiratory function in healthy children aged 2-7 years in whom we measured respiratory resistance by the interrupter technique (Rint); total respiratory impedance (Zrs), respiratory resistance (Rrs), and reactance (Xrs) by the impulse oscillation technique; and specific airway resistance (sRaw) by a modified procedure method in the whole body plethysmograph. Measurements were attempted in 151 children and were successfully obtained in 121 children with a mean (SD) age of 5.3 (1.5) years; no measurements were possible in 30 children (mean age 3 (0.9) years). The repeatability of measurements was independent of the age of the subjects, and the within-subject coefficient of variation was 11.1%, 8.1%, 10.8%, and 10.2% for sRaw, Rint, Zrs, and Rrs at 5 Hz (Rrs5), respectively. All lung function indices were linearly related to age, height, and weight. A significant negative correlation with age, height, and weight was found for Rint, Zrs, and Rrs5. Xrs5 was positively correlated to age and body size. The mean values of Rint, Rrs5, Xrs5, and Zrs in children younger and older than 5 years were 1.04, 1.38, -0.5, and 1.48 kPa x L(-1) x s and 0.9, 1.18, -0.37, and 1.23 kPa x L(-1) x s, respectively. sRaw showed no significant correlation with body size or age and the mean sRaw in children younger and older than 5 years was 1.09 and 1.13 kPa x s, respectively. None of the indices of respiratory function differed between boys and girls. Xrs and Rrs exhibited a significant frequency dependence in the range of 5-35 Hz. The techniques applied in this study require minimal cooperation and allow measurement of lung function in 80% of our population of awake young children. Further studies are needed to evaluate the potentials of the presently established reference values for clinical and epidemiological purposes.

Entities:  

Mesh:

Year:  1998        PMID: 9635934     DOI: 10.1002/(sici)1099-0496(199805)25:5<322::aid-ppul6>3.0.co;2-k

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  18 in total

1.  Airway resistance measured by the interrupter technique: normative data for 2-10 year olds of three ethnicities.

Authors:  S A McKenzie; E Chan; I Dundas; P D Bridge; C S Pao; M Mylonopoulou; M J R Healy
Journal:  Arch Dis Child       Date:  2002-09       Impact factor: 3.791

2.  Age dependent systemic exposure to inhaled salbutamol.

Authors:  Klaus Bønnelykke; Jakob Jessing Jespersen; Hans Bisgaard
Journal:  Br J Clin Pharmacol       Date:  2007-03-01       Impact factor: 4.335

3.  Respiratory function in healthy young children using forced oscillations.

Authors:  Graham L Hall; Peter D Sly; Takayoshi Fukushima; Merci M Kusel; Peter J Franklin; Friedrich Horak; Hilary Patterson; Catherine Gangell; Stephen M Stick
Journal:  Thorax       Date:  2007-01-24       Impact factor: 9.139

4.  Short and long term variability of the interrupter technique under field and standardised conditions in 3-6 year old children.

Authors:  R M J Beelen; H A Smit; R T van Strien; L P Koopman; J E Brussee; B Brunekreef; J Gerritsen; P J F M Merkus
Journal:  Thorax       Date:  2003-09       Impact factor: 9.139

5.  Skeletal dysplasias: evaluation with impulse oscillometry and thoracoabdominal motion analysis.

Authors:  M E Rodriguez; William G Mackenzie; Colleen Ditro; Thomas L Miller; Aaron Chidekel; Thomas H Shaffer
Journal:  Pediatr Pulmonol       Date:  2010-07

6.  Spirometry and Impulse Oscillometry in Preschool Children: Acceptability and Relationship to Maternal Smoking in Pregnancy.

Authors:  Meyer Kattan; Leonard B Bacharier; George T O'Connor; Robyn Cohen; Ronald L Sorkness; Wayne Morgan; Peter J Gergen; Katy F Jaffee; Cynthia M Visness; Robert A Wood; Gordon R Bloomberg; Susan Doyle; Ryan Burton; James E Gern
Journal:  J Allergy Clin Immunol Pract       Date:  2018-02-13

7.  Reference values of interrupter respiratory resistance in healthy preschool white children.

Authors:  E Lombardi; P D Sly; G Concutelli; E Novembre; G Veneruso; G Frongia; R Bernardini; A Vierucci
Journal:  Thorax       Date:  2001-09       Impact factor: 9.139

8.  Analysis of impulse oscillometric measures of lung function and respiratory system model parameters in small airway-impaired and healthy children over a 2-year period.

Authors:  Erika G Meraz; Homer Nazeran; Carlos D Ramos; Pat Nava; Bill Diong; Michael D Goldman; Christine A Goldman
Journal:  Biomed Eng Online       Date:  2011-03-25       Impact factor: 2.819

Review 9.  Pulmonary function testing in young children.

Authors:  Hugo Escobar; Terrence W Carver
Journal:  Curr Allergy Asthma Rep       Date:  2011-12       Impact factor: 4.806

Review 10.  Endpoints for clinical trials in young children with cystic fibrosis.

Authors:  Stephanie D Davis; Alan S Brody; Mary J Emond; Lyndia C Brumback; Margaret Rosenfeld
Journal:  Proc Am Thorac Soc       Date:  2007-08-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.