Literature DB >> 9630061

Duration of acute exposures to vibration and finger circulation.

M Bovenzi1, C J Lindsell, M J Griffin.   

Abstract

OBJECTIVES: This study investigated changes in finger circulation after different durations of exposure to hand-transmitted vibration.
METHODS: Finger skin temperature (FST), finger blood flow (FBF), and finger systolic blood pressure (FSBP) were measured in the middle fingers of both hands of 10 healthy men. Finger vascular resistance was also estimated. The right hand was exposed for 7.5, 15, and 30 minutes (static load 10 N) to 125-Hz vibration (root-mean-square acceleration 87 m/s2). Static load only was used as a control. Finger circulation was measured before the vibration and static load exposure and at fixed intervals during exposure and a 45-minute recovery period.
RESULTS: No significant changes were found with the static load. The FST and FSBP did not change significantly during vibration exposure, whereas vibration produced significant reductions in FBF and increases in vascular resistance at each duration when compared with preexposure and contralateral (non-vibrated) finger values. Temporary vasodilation occurred in the vibrated finger immediately after each vibration exposure. Recovery was complete for FBF and vascular resistance after the 7.5-minute vibration, whereas a progressive FBF reduction occurred in both the vibrated and the nonvibrated fingers after 15- and 30-minute exposure. The longer the duration of vibration exposure, the stronger the vasoconstriction in the vibrated finger during recovery.
CONCLUSIONS: Vasoregulatory mechanisms mediated by both intrinsic (local) and extrinsic (neural or endocrine) control systems seem to be related to digital circulatory changes during 125-Hz vibration. It is concluded that, not only the frequency and magnitude of vibration, but also its duration contributes to the reaction of the digital vessels to acute vibration.

Entities:  

Mesh:

Year:  1998        PMID: 9630061     DOI: 10.5271/sjweh.290

Source DB:  PubMed          Journal:  Scand J Work Environ Health        ISSN: 0355-3140            Impact factor:   5.024


  18 in total

1.  Acute vascular responses to the frequency of vibration transmitted to the hand.

Authors:  M Bovenzi; C J Lindsell; M J Griffin
Journal:  Occup Environ Med       Date:  2000-06       Impact factor: 4.402

2.  Response of finger circulation to energy equivalent combinations of magnitude and duration of vibration.

Authors:  M Bovenzi; C J Lindsell; M J Griffin
Journal:  Occup Environ Med       Date:  2001-03       Impact factor: 4.402

3.  Acute effects of continuous and intermittent vibration on finger circulation.

Authors:  Massimo Bovenzi; Alexandra J L Welsh; Michael J Griffin
Journal:  Int Arch Occup Environ Health       Date:  2004-03-18       Impact factor: 3.015

4.  Acute effects of mechanical shocks on finger blood flow: influence of shock repetition rate and shock magnitude.

Authors:  Ying Ye; Marcella Mauro; Massimo Bovenzi; Michael J Griffin
Journal:  Int Arch Occup Environ Health       Date:  2011-10-02       Impact factor: 3.015

5.  Effects of temperature on reductions in finger blood flow induced by vibration.

Authors:  Ying Ye; Michael J Griffin
Journal:  Int Arch Occup Environ Health       Date:  2010-07-14       Impact factor: 3.015

6.  Reductions in finger blood flow induced by 125-Hz vibration: effect of location of contact with vibration.

Authors:  Ying Ye; Michael J Griffin
Journal:  Int Arch Occup Environ Health       Date:  2015-08-05       Impact factor: 3.015

7.  Assessment of room temperature influence on finger blood flow response induced by short-term grasping of vibrating handle.

Authors:  M H Mahbub; M Inoue; K Yokoyama; M S Laskar; H Ohnari; K Suizu; J Inagaki; Y Takahashi; N Harada
Journal:  Int Arch Occup Environ Health       Date:  2005-07-27       Impact factor: 3.015

8.  Acute effects of force and vibration on finger blood flow.

Authors:  M Bovenzi; A J L Welsh; A Della Vedova; M J Griffin
Journal:  Occup Environ Med       Date:  2006-02       Impact factor: 4.402

9.  Digital blood flow and temperature responses in palmar and dorsal skin induced by short-term vibration exposure while grasping a vibratory handle.

Authors:  M H Mahbub; Noriaki Harada
Journal:  Int Arch Occup Environ Health       Date:  2007-12-05       Impact factor: 3.015

10.  Effect of the magnitude and frequency of hand-transmitted vibration on finger blood flow during and after exposure to vibration.

Authors:  Alexandra J L Thompson; Michael J Griffin
Journal:  Int Arch Occup Environ Health       Date:  2009-03-24       Impact factor: 3.015

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.