Literature DB >> 9627337

Influence of the heterogeneity of P-glycoprotein expression on technetium-99m-MIBI uptake in breast cancer.

L Kostakoglu1, S Ruacan, E L Ergün, I Sayek, N Elahi, C F Bekdik.   

Abstract

UNLABELLED: We prospectively studied a total of 30 patients with breast cancer to evaluate the relationship between the degree of accumulation of 99mTc-sestamibi (MIBI) and the heterogeneity of p-glycoprotein expression in tumor tissues.
METHODS: Twenty patients during initial presentation and 10 patients during post-therapy evaluation underwent contemporaneous 99mTc-MIBI imaging and surgery or biopsy. Immunohistochemical studies were performed on multiple nonconsecutive sections of the same tumor using a p-glycoprotein-specific monoclonal antibody, JSB-1. Tumor-to-background (T/B) ratios were correlated with the level and heterogeneity of p-glycoprotein expression determined by immunohistochemical studies.
RESULTS: The T/B ratios were lower for those tumors with strong p-glycoprotein expression (Group 1) than those with strong-to-weak expression (Group 2) or those with weak-to-no expression (Group 3) (1.32 +/- 0.19 and 1.85 +/- 0.56 and 2.86 +/- 1.06, respectively). There was statistically significant difference in T/B ratios between all 3 groups (p < 0.005). Although T/B ratios for Group 1 and Group 3 were clearly distinct from one another with no overlapping values, the values for Group 2 overlapped with those of Group 1 and Group 3. When we evaluated the entire patient group with excluding those with strong-to-weak expression, although the p value remained the same (p < 0.001), we obtained a stronger correlation between T/B ratios and p-glycoprotein expression (r = 0.808 versus 0.735).
CONCLUSION: Due to the heterogeneous expression of p-glycoprotein, both immunohistochemistry and 99mTc-MIBI scintigraphy may yield confounding results by contrasting with one another if the presence or absence of p-glycoprotein is not extensively explored. Although our data confirmed that 99mTc-MIBI imaging is useful in the determination of the presence of multidrug resistance in patients with breast cancer, the issue of heterogeneous expression of the antigen should be further investigated when unexpected results are obtained.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9627337

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  2 in total

Review 1.  Use of tomographic nuclear medicine procedures, SPECT and pinhole SPECT, with cationic lipophilic radiotracers for the evaluation of axillary lymph node status in breast cancer patients.

Authors:  Giuseppe Madeddu; Angela Spanu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-04-15       Impact factor: 9.236

Review 2.  The role of SPET and PET in monitoring tumour response to therapy.

Authors:  Chariklia Giannopoulou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-06-14       Impact factor: 9.236

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.