Comparison of mean skin temperature using 'covered' versus 'uncovered' contact thermistors.

M J Buono1, R L Ulrich.   

Abstract

The purpose of this study was to compare the mean skin temperature (Tsk) obtained using 'covered' versus 'uncovered' contact thermistors in a variety of environmental conditions. Ten male subjects walked on a treadmill at 6.4 kph for 30 min in three different environments: thermoneutral (23 degrees C/50% RH), hot-humid (35 degrees C/80%), and hot-dry (42 degrees C/20%). Tsk was measured using three 'uncovered' contact thermistors, and three 'covered' thermistors. The 'uncovered' probes were attached using acrylic rings that allowed the outer surface of the thermistors to have free exchange with the environment. The 'covered' probes were affixed to the skin using foam patches and tape. The latter procedure is commonly used in many research and clinical laboratories. The 'covered' probes resulted in a significantly (p < 0.05) higher Tsk under all three environmental conditions. The largest difference occurred in the thermoneutral condition with the 'covered' Tsk being 1.3 degrees C higher than the 'uncovered' Tsk. These results suggest that covering a contact skin thermistor hinders heat loss and results in an artificially high Tsk. It is hoped that the results of this study will encourage the adoption of 'uncovered' contact skin thermistors in the future.

Entities:  

Mesh:

Year:  1998        PMID: 9626693     DOI: 10.1088/0967-3334/19/2/016

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  9 in total

1.  Prediction of human core body temperature using non-invasive measurement methods.

Authors:  Reto Niedermann; Eva Wyss; Simon Annaheim; Agnes Psikuta; Sarah Davey; René Michel Rossi
Journal:  Int J Biometeorol       Date:  2013-06-13       Impact factor: 3.787

2.  Effect of ambient temperature and attachment method on surface temperature measurements.

Authors:  Agnes Psikuta; Reto Niedermann; René M Rossi
Journal:  Int J Biometeorol       Date:  2013-05-19       Impact factor: 3.787

3.  Validation of the thermophysiological model by Fiala for prediction of local skin temperatures.

Authors:  Natividad Martínez; Agnes Psikuta; Kalev Kuklane; José Ignacio Priego Quesada; Rosa María Cibrián Ortiz de Anda; Pedro Pérez Soriano; Rosario Salvador Palmer; José Miguel Corberán; René Michel Rossi; Simon Annaheim
Journal:  Int J Biometeorol       Date:  2016-05-25       Impact factor: 3.787

4.  Multi-sector thermo-physiological head simulator for headgear research.

Authors:  Natividad Martinez; Agnes Psikuta; José Miguel Corberán; René M Rossi; Simon Annaheim
Journal:  Int J Biometeorol       Date:  2016-09-09       Impact factor: 3.787

5.  Umbilical temperature correlation with core and skin temperatures at rest, in the heat and during physical activity.

Authors:  Raymond J Roberge; Jung-Hyun Kim; Patrick Yorio; Aitor Coca; Yongsuk Seo; Tyler Quinn; Ali Aljaroudi; Jeffrey B Powell
Journal:  Int J Hyperthermia       Date:  2017-04-19       Impact factor: 3.914

6.  A comparison between conductive and infrared devices for measuring mean skin temperature at rest, during exercise in the heat, and recovery.

Authors:  Aaron J E Bach; Ian B Stewart; Alice E Disher; Joseph T Costello
Journal:  PLoS One       Date:  2015-02-06       Impact factor: 3.240

Review 7.  Skin Temperature Measurement Using Contact Thermometry: A Systematic Review of Setup Variables and Their Effects on Measured Values.

Authors:  Braid A MacRae; Simon Annaheim; Christina M Spengler; René M Rossi
Journal:  Front Physiol       Date:  2018-01-30       Impact factor: 4.566

8.  A Wearable Textile Thermograph.

Authors:  Pasindu Lugoda; Theodore Hughes-Riley; Rob Morris; Tilak Dias
Journal:  Sensors (Basel)       Date:  2018-07-21       Impact factor: 3.576

9.  A Thermal Skin Model for Comparing Contact Skin Temperature Sensors and Assessing Measurement Errors.

Authors:  Braid A MacRae; Christina M Spengler; Agnes Psikuta; René M Rossi; Simon Annaheim
Journal:  Sensors (Basel)       Date:  2021-07-19       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.