Public locations of cardiac arrest. Implications for public access defibrillation.

L Becker1, M Eisenberg, C Fahrenbruch, L Cobb.   

Abstract

BACKGROUND: The purpose of this study was to describe the public locations of cardiac arrest and to estimate the annual incidence of cardiac arrest per site to determine optimal placement of automatic external defibrillators (AEDs). This was a retrospective cohort study. METHODS AND
RESULTS: Locations of cardiac arrest were abstracted from data collected by emergency medical service programs in Seattle and King County, Washington, from January 1, 1990, through December 31, 1994. Types of commercial and civic establishments were tallied and grouped into 23 location categories consistent with Standard Industrial Codes, and the number of sites within each location category was determined. With the addition of "public outdoors" and "automobiles" as categories, there were 25 location categories. During the study period, 7185 arrests occurred, 1130 (16%) of which were in public locations. An annual incidence of cardiac arrest per site was calculated. Ten location categories with 172 sites were identified as having a higher incidence of cardiac arrest (> or = .03 per year per site). Thirteen location categories had a lower incidence of arrest (< or = .01 per year per site). There were approximately 71,000 sites within these categories.
CONCLUSIONS: Placement of 276 AEDs in the 172 higher-incidence sites would have provided treatment for 134 cardiac arrest patients in a 5-year period, 60% of whom were in ventricular fibrillation. We estimate between 8 and 32 lives could be saved in 5 years. To cover the remaining 347 arrests occurring in public in a 5-year period, defibrillators would have to be placed in 71,000 sites, not including outdoors and automobiles. Placement of AEDs in public locations can be guided by the site-specific incidence of arrest.

Entities:  

Mesh:

Year:  1998        PMID: 9626169     DOI: 10.1161/01.cir.97.21.2106

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  42 in total

1.  Cost-effectiveness of automated external defibrillator deployment in selected public locations.

Authors:  Peter Cram; Sandeep Vijan; A Mark Fendrick
Journal:  J Gen Intern Med       Date:  2003-09       Impact factor: 5.128

2.  Outcome after cardiac arrest outside hospital.

Authors:  Johan Engdahl
Journal:  BMJ       Date:  2002-09-07

3.  The debate on public place defibrillators: charged but shockingly ill informed.

Authors:  J P Pell
Journal:  Heart       Date:  2003-12       Impact factor: 5.994

4.  Pharmacy students' retention of knowledge and skills following training in automated external defibrillator use.

Authors:  Karen Birckelbaw Kopacek; Anna Legreid Dopp; John M Dopp; Orly Vardeny; J Jason Sims
Journal:  Am J Pharm Educ       Date:  2010-08-10       Impact factor: 2.047

Review 5.  Automated external defibrillators and secondary prevention of sudden cardiac death among children and adolescents.

Authors:  Joshua Kovach; Stuart Berger
Journal:  Pediatr Cardiol       Date:  2012-03       Impact factor: 1.655

Review 6.  [Position paper on "automated external defibrillation" ].

Authors:  H-J Trappe; D Andresen; H-R Arntz; H-J Becker; K Werdan
Journal:  Z Kardiol       Date:  2005-04

7.  Reality of out of hospital cardiac arrest.

Authors:  M F O'Rourke
Journal:  Heart       Date:  2005-05-27       Impact factor: 5.994

8.  [First responder defibrillation in the LAGO-die Therme--results and experiences].

Authors:  H-J Trappe; M Nesslinger; O M Schrage; H Wissuwa; H-J Becker
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2005-06

9.  [Position paper on "Automatic external defibrillation"].

Authors:  H-J Trappe; D Andresen; H-R Arntz; H-J Becker; K Werdan
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2005-06

Review 10.  [Public access defibrillation. Limited use by trained first responders and laymen].

Authors:  S Maisch; P Friederich; A E Goetz