An investigation into the dosimetry of a nine-field tomotherapy irradiation using BANG-gel dosimetry.

M Oldham1, I Baustert, C Lord, T A Smith, M McJury, A P Warrington, M O Leach, S Webb.   

Abstract

BANG-gel dosimetry offers the potential for measuring the dose delivered by a radiotherapy treatment technique, in three dimensions, with high spatial resolution and good accuracy. The ability to measure comprehensively a 3D dose distribution is a major advantage of the gel dosimeter over conventional planar and point-based dosimeter devices, particularly when applied to the verification of complex dose distributions characteristic of intensity-modulated radiotherapy (IMRT). In this paper an in-house manufactured BANG-gel dosimeter was applied to study the dose distributions of two irradiation experiments for which the distributions were known: (i) a dosimetrically simple parallel-opposed irradiation, and (ii) a more complex nine-field 'static tomotherapy' intensity-modulated irradiation delivered with the Nomos MIMiC. The uniform distribution in (i) allowed a study of the magnetic resonance (MR) imaging parameters to achieve an optimal trade-off between noise and image resolution (optimum image resolution for the Siemens 1.5T Vision system was determined to be approximately 0.8 mm2 with a slice thickness of 2 mm). The spatial uniformity of gel sensitivity to radiation was found to depend strongly on the presence of oxygen, which must be eliminated for the gel dosimeter to be of use. The gel dosimeter was found to agree well with predicted dose distributions and accurately measured the steep penumbral fall-off of dose, even after many days, proving its potential for the verification of IMRT distributions. In the nine-field IMRT delivery (ii) the predicted dose was computed by both an in-house 'component-delivery' dose algorithm and the Peacock planning-system dose algorithm. Good agreement was found between the two algorithms despite the latter's omission of the change in penumbral characteristics with aperture-size during delivery, lack of inhomogeneity correction and approximate modelling of leaf leakage. These effects were found to be small for the problem studied. The predicted distribution agreed well with the gel-measured distribution at medium and high doses (50-90% isodose lines) although differences of up to 10% were observed at lower doses (30% isodose line). The gel dosimeter was found to have the potential to verify IMRT distributions but required considerable care to achieve accurate results. Attention was required to achieve uniformity of gel sensitivity (to prevent oxygen contamination), and in the calibration process.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9623644     DOI: 10.1088/0031-9155/43/5/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Characterization of a new radiochromic three-dimensional dosimeter.

Authors:  P Y Guo; J A Adamovics; M Oldham
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

2.  Optical-CT scanning of polymer gels.

Authors:  M Oldham
Journal:  J Phys Conf Ser       Date:  2004

3.  A practical three-dimensional dosimetry system for radiation therapy.

Authors:  Pengyi Guo; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

4.  Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation.

Authors:  H S Sakhalkar; M Oldham
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

Review 5.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

6.  MAGAT gel and EBT2 film-based dosimetry for evaluating source plugging-based treatment plan in Gamma Knife stereotactic radiosurgery.

Authors:  Gopishankar Natanasabapathi; Vivekanandhan Subbiah; Shashank Sharad Kale; Goura Kishor Rath; S Senthilkumaran; Sanjay Thulkar; Vellaiyan Subramani; M A Laviraj; Raj Kishor Bisht; A K Mahapatra
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

7.  CT gel dosimetry technique: comparison of a planned and measured 3D stereotactic dose volume.

Authors:  C Audet; M Hilts; A Jirasek; C Duzenli
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

8.  Uncertainty Analysis in MRI-based Polymer Gel Dosimetry.

Authors:  M Keshtkar; M H Zahmatkesh; A R Montazerabadi
Journal:  J Biomed Phys Eng       Date:  2017-09-01

9.  Determination of paramagnetic ferrous gel sensitivity in low energy x-ray beam produced by a miniature accelerator.

Authors:  Yassir Ben Ahmed; Jérémy Coulaud; Soléakhena Ken; Laure Parent
Journal:  PLoS One       Date:  2020-05-04       Impact factor: 3.240

Review 10.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.