S Sugiura1, N Kobayakawa, H Fujita, H Yamashita, S Momomura, S Chaen, M Omata, H Sugi.
Abstract
To provide information on the mechanism of cardiac adaptation at the molecular level, we compared the unitary displacements and forces between the 2 rat cardiac myosin isoforms, V1 and V3. A fluorescently labeled actin filament, with a polystyrene bead attached, was caught by an optical trap and brought close to a glass surface sparsely coated with either of the 2 isoforms, so that the actin-myosin interaction took place in the presence of a low concentration of ATP (0.5 micromol/L). Discrete displacement events were recorded with a low trap stiffness (0.03 to 0.06 pN/nm). Frequency distribution of the amplitude of the displacements consisted of 2 gaussian curves with peaks at 9 to 10 and 18 to 20 nm for both V1 and V3, suggesting that 9 to 10 nm is the unitary displacement for both isoforms. The duration of the displacement events was longer for V3 than for V1. On the other hand, discrete force transients were recorded with a high trap stiffness (2.1 pN/nm), and their amplitude showed a broad distribution with mean values between 1 and 2 pN for V1 and V3. The durations of the force transients were also longer for V3 than for V1. These results indicate that both the unitary displacements and forces are similar in amplitude but different in duration between the 2 cardiac myosin isoforms, being consistent with the reports that the tension cost is higher in muscles consisting mainly of V1 than those consisting mainly of V3.Entities:
Mesh:
Substances:
Year: 1998 PMID: 9622155 DOI: 10.1161/01.res.82.10.1029