Literature DB >> 9620081

Noninvasive investigations of the normal ocular circulation in humans.

L Schmetterer1, S Dallinger, O Findl, K Strenn, U Graselli, H G Eichler, M Wolzt.   

Abstract

PURPOSE: To compare the reproducibility of laser interferometric measurements of fundus pulsation, pneumatonometric measurement of pulse amplitude (PA) and pulsatile ocular blood flow (POBF), and Doppler ultrasonic measurements of blood flow velocity in the ophthalmic artery (OA) and the posterior ciliary arteries (PCAs) and to investigate the association of the results obtained with these methods and to characterize ocular hemodynamics during Valsalva maneuver and isometric handgrip.
METHODS: All studies were performed in healthy subjects. Fundus pulsation (n = 48), POBF (n = 24), and blood flow velocities (n = 24) were measured at baseline and during the Valsalva maneuver and isometric handgrip. Intraclass correlation coefficients were calculated for test/retest variability, for short-term variability, and for interobserver variability.
RESULTS: Intraclass correlation coefficients were between 0.95 and 0.98 for fundus pulsation measurements, between 0.54 and 0.76 for pneumatonometric measurements, between 0.44 and 0.88 for Doppler sonographic measurements in the OA and between 0.32 and 0.60 in the PCAs. There was a high degree of association between pneumatonometric parameters and fundus pulsation amplitude. Valsalva maneuver significantly reduced fundus pulsations, PA, and POBF, whereas isometric handgripping did not change these parameters.
CONCLUSIONS: The reproducibility of fundus pulsation measurements was excellent. Reproducibility of pneumatonometric parameters and ultrasonographic measurements in the OA was satisfactory. Reproducibility of ultrasonographic measurements in the PCAs was low. Data obtained during the autonomic stimuli experiments argue against the sole use of systems to measure pulsatile blood flow, if no additional data on flow pulsatility are available. At least in cases when changes in blood pressure are likely to occur the ratio of pulsatile to nonpulsatile blood flow might not be constant and POBF might not be an adequate measure of total ocular blood flow.

Entities:  

Mesh:

Year:  1998        PMID: 9620081

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  18 in total

1.  The effect of simulated obstructive apnoea on intraocular pressure and pulsatile ocular blood flow in healthy young adults.

Authors:  P O Lundmark; G E Trope; J G Flanagan
Journal:  Br J Ophthalmol       Date:  2003-11       Impact factor: 4.638

2.  Twelve hour reproducibility of choroidal blood flow parameters in healthy subjects.

Authors:  E Polska; K Polak; A Luksch; G Fuchsjager-Mayrl; V Petternel; O Findl; L Schmetterer
Journal:  Br J Ophthalmol       Date:  2004-04       Impact factor: 4.638

3.  Evaluation of ocular pulse amplitude and choroidal thickness in diabetic macular edema.

Authors:  Y Totan; T K Akyüz; E Güler; F B Güragaç
Journal:  Eye (Lond)       Date:  2015-11-13       Impact factor: 3.775

4.  Effect of nimodipine on ocular blood flow and colour contrast sensitivity in patients with normal tension glaucoma.

Authors:  A Luksch; G Rainer; D Koyuncu; P Ehrlich; T Maca; M E Gschwandtner; C Vass; L Schmetterer
Journal:  Br J Ophthalmol       Date:  2005-01       Impact factor: 4.638

5.  Effect of a nifedipine induced reduction in blood pressure on the association between ocular pulse amplitude and ocular fundus pulsation amplitude in systemic hypertension.

Authors:  M Bayerle-Eder; J Kolodjaschna; M Wolzt; E Polska; S Gasic; L Schmetterer
Journal:  Br J Ophthalmol       Date:  2005-06       Impact factor: 4.638

6.  Pharmacokinetic-pharmacodynamic profile of systemic nitric oxide-synthase inhibition with L-NMMA in humans.

Authors:  B X Mayer; C Mensik; S Krishnaswami; H Derendorf; H G Eichler; L Schmetterer; M Wolzt
Journal:  Br J Clin Pharmacol       Date:  1999-05       Impact factor: 4.335

7.  Ocular haemodynamics and colour contrast sensitivity in patients with type 1 diabetes.

Authors:  O Findl; S Dallinger; B Rami; K Polak; E Schober; A Wedrich; E Ries; H G Eichler; M Wolzt; L Schmetterer
Journal:  Br J Ophthalmol       Date:  2000-05       Impact factor: 4.638

8.  Unrecordable pulsatile ocular blood flow may signify severe stenosis of the ipsilateral internal carotid artery.

Authors:  Y Barkana; A Harris; L Hefez; M Zaritski; D Chen; I Avni
Journal:  Br J Ophthalmol       Date:  2003-12       Impact factor: 4.638

9.  Response of choroidal blood flow to carbogen breathing in smokers and non-smokers.

Authors:  B Wimpissinger; H Resch; F Berisha; G Weigert; L Schmetterer; K Polak
Journal:  Br J Ophthalmol       Date:  2004-06       Impact factor: 4.638

10.  Perimetric and retrobulbar blood flow changes following carotid endarterectomy.

Authors:  Vassilios P Kozobolis; Efstathios T Detorakis; George S Georgiadis; Athanassios A Achtaropoulos; Theofanis T Papas; Miltos K Lazarides
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2007-04-25       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.