Literature DB >> 9619926

The Metal-Cancellous Cementless Lübeck total hip arthroplasty. Five-to-nine-year results.

M Matsui1, K Nakata, K Masuhara, K Ohzono, N Sugano, T Ochi.   

Abstract

We implanted 51 Metal-Cancellous Cementless Lübeck (MCCL) prostheses into 45 patients with dysplastic hips and followed 49 hips (96.1%) for five to nine years. One had needed revision for stem fracture and one for infection; the clinical outcome of the other 47 hips was assessed using the Merle d'Aubigné and Postel hip score. All hips were either excellent (63%) or good (37%). Three patients (6%) had mild thigh pain at six months, but this had settled within two years. Serial radiographs showed stable fixation with bone ingrowth in all hips, with increased density of the cancellous bone in contact with the implant and some trabecular ingrowth. There was early varus shift of the stem in one hip, but this stabilised in three months. Osteolysis of the femoral cortex was seen in one hip at seven years after surgery, and mild bone resorption due to stress shielding in 31 (63%). Acetabular bone grafting with autogenous bone from the femoral head gave successful support to the socket in 13 hips. The MCCL prosthesis gave satisfactory mid-term results in patients with osteoarthritis secondary to hip dysplasia.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9619926     DOI: 10.1302/0301-620x.80b3.8108

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  5 in total

1.  [Cementless stems of the hip. Current status].

Authors:  H Effenberger; M Imhof; U Witzel; S Rehart
Journal:  Orthopade       Date:  2005-05       Impact factor: 1.087

2.  Effect of proximal femoral osteoporosis on cementless hip arthroplasty: a short-term clinical analysis.

Authors:  Xian-feng Lou; Yu-hong Li; Xiang-jin Lin
Journal:  J Zhejiang Univ Sci B       Date:  2007-01       Impact factor: 3.066

3.  [Long-term results of thrust plate prostheses: comparison of patients younger than and older than 50 years].

Authors:  S Wienbeck; N Osada; E Basad; H Stürz; B A Ishaque
Journal:  Orthopade       Date:  2011-03       Impact factor: 1.087

4.  Three-year follow-up of changes of cortical bone thickness after implantation of Endo-Exo-Prosthesis (EEP) for transfemoral amputees.

Authors:  Marcus Örgel; Emmanouil Liodakis; Pratya Jaratjitwilai; Afif Harb; Nils Wirries; Mohamed Omar; Christian Krettek; Horst-Heinrich Aschoff
Journal:  J Orthop Surg Res       Date:  2020-05-04       Impact factor: 2.359

5.  19 years outcome after cementless total hip arthroplasty with spongy metal structured implants in patients younger than 65 years.

Authors:  Ludger Gerdesmeyer; Munjed Al Muderis; Hans Gollwitzer; Norbert Harrasser; Martin Stukenberg; Maria-Angela Clifford; Andreas Toepfer
Journal:  BMC Musculoskelet Disord       Date:  2016-10-18       Impact factor: 2.362

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.