Biocompatibility response to modified Baerveldt glaucoma drains.

J T Jacob1, C F Burgoyne, S J McKinnon, T M Tanji, P K LaFleur, E Duzman.   

Abstract

Glaucoma implants are designed to increase fluid outflow from the eye in order to decrease intraocular pressure and prevent damage to the optic nerve. The implant consists of a silicone tube that is inserted into the anterior chamber at one end and is attached at the other end to a silicone plate that is sutured to the outside of the globe beneath the conjunctiva. The glaucoma "implant" becomes a "drain" over the first 3 to 6 postoperative weeks as the silicone plate is enclosed by a fibrous capsule that allows a space to form into which fluid can drain and from which fluid can be absorbed by the surrounding tissues. Ideally, the size and thickness of the capsule (the filtering bleb) that surrounds the plate is such that the amount of fluid that passes through the capsule is identical to the amount of fluid produced by the eye at an intraocular pressure of 8 to 14 mmHg. The most common long-term complication of these implants is failure of the filtering bleb 2 to 4 years after surgery due to the formation of a thick fibrous capsule around the device. Micromovement of the smooth drainage plate against the scleral surface may be integral to the mechanism of glaucoma implant failure by stimulating low-level activation of the wound healing response, increased collagen scar formation, and increased fibrous capsule thickness. To test this hypothesis, we modified seven Baerveldt implants by adding porous cellular ingrowth material to the posterior surface of the drainage plate. Seven modified and five unmodified implants were placed in adult rabbit eyes. After 6 months, we found that the fibrous capsule around the modified implants was significantly thinner than the capsule surrounding the unmodified implants (p < 0.05), particularly on the surface between the porous ingrowth material and the sclera (p < 0.05). Although type I collagen predominated in the fibrous capsules around both types of implants, the amount of type III collagen in the capsules around the modified implants was significantly less than the amount around the unmodified implants (p < 0.05). We believe that these data suggest a reduction in the wound healing response to the modified implants, with greater stability of capsule thickness. Long-term studies are needed to verify that the stability of the capsules around the modified implants persists over a period of years, in which case this type of modification may prove useful in prolonging the functional life of these devices in the surgical treatment of glaucoma.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9619427     DOI: 10.1002/(sici)1097-4636(199822)43:2<99::aid-jbm3>3.0.co;2-g

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  10 in total

1.  The Ahmed glaucoma valve in neovascular glaucoma (An AOS Thesis).

Authors:  Peter A Netland
Journal:  Trans Am Ophthalmol Soc       Date:  2009-12

2.  In vivo and in vitro response to electrochemically anodized Ti-6Al-4V alloy.

Authors:  Yu Mi Lee; Eun Jung Lee; Sung Tae Yee; Byung Il Kim; Eun Sang Choe; Hyun Wook Cho
Journal:  J Mater Sci Mater Med       Date:  2007-10-04       Impact factor: 3.896

3.  One-Year Feasibility Study of Replenish MicroPump for Intravitreal Drug Delivery: A Pilot Study.

Authors:  Juan-Carlos Gutiérrez-Hernández; Sean Caffey; Walid Abdallah; Phillip Calvillo; Roberto González; Jason Shih; Jeff Brennan; Jenna Zimmerman; Juan-Carlos Martínez-Camarillo; Anthony R Rodriguez; Rohit Varma; Arturo Santos; Gisela Sánchez; Mark Humayun
Journal:  Transl Vis Sci Technol       Date:  2014-07-01       Impact factor: 3.283

4.  Comparison of two prototypes of a magnetically adjustable glaucoma implant in rabbits.

Authors:  Birthe Schwerk; Lisa Harder; Claudia Windhövel; Marion Hewicker-Trautwein; Anna Wagner; Jan-Peter Bach; Lena Carolin Voigt; Ulf Hinze; Boris Chichkov; Heinz Haferkamp; Holger Lubatschowski; Stephan Nikolic; Ingo Nolte
Journal:  PLoS One       Date:  2019-04-11       Impact factor: 3.240

5.  Effects of aqueous suppressants and prostaglandin analogues on early wound healing after glaucoma implant surgery.

Authors:  Kyoung In Jung; Jung Eun Woo; Chan Kee Park
Journal:  Sci Rep       Date:  2019-03-27       Impact factor: 4.379

6.  Biocompatibility and Biological Corrosion Resistance of Ti-39Nb-6Zr+0.45Al Implant Alloy.

Authors:  Yu-Jin Hwang; Young-Sin Choi; Yun-Ho Hwang; Hyun-Wook Cho; Dong-Geun Lee
Journal:  J Funct Biomater       Date:  2020-12-29

7.  Biocompatibility and feasibility of VisiPlate, a novel ultrathin, multichannel glaucoma drainage device.

Authors:  Brandon W Kao; Elana Meer; Thomas A Barbolt; Richard A Lewis; Iqbal Ike Ahmed; Vivian Lee; Samuel M Nicaise; Georgia Griggs; Eydie G Miller-Ellis
Journal:  J Mater Sci Mater Med       Date:  2021-11-24       Impact factor: 3.896

8.  Conjunctival expansion using a subtenon's silicone implant in New Zealand white rabbits.

Authors:  Ie-na Yoon; Dong-hoon Lee; Sang-hoon Rah
Journal:  Yonsei Med J       Date:  2007-12-31       Impact factor: 2.759

9.  Pirfenidone inhibits fibrosis in foreign body reaction after glaucoma drainage device implantation.

Authors:  Kyoung In Jung; Chan Kee Park
Journal:  Drug Des Devel Ther       Date:  2016-04-15       Impact factor: 4.162

10.  A One-Year Follow-Up of Two Ahmed Glaucoma Valve Models (S2 and FP7) for Refractory Glaucoma: A Prospective Randomized Trial.

Authors:  Khaled Hamdi Elbaklish; Wael Adel Gomaa
Journal:  Clin Ophthalmol       Date:  2020-03-04
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.