Literature DB >> 9614744

Cardiokymograph system with a capacitance transducer and its preliminary application in the measurement of heart wall movement.

W Q Ge1, Z C Luo, J Jin, Y C Huang, S Wang, S J Lui.   

Abstract

A novel cardiokymograph system is introduced. The new system features a capacitance transducer with increased sensitivity and can be used in multichannel measurements. The novelty of this technique is the injection of a current into the patient coupled with the use of a capacitive displacement transducer and the possibility of multichannel monitoring. It provides for the possibility of removing breath noise when some signal processing technique, such as adaptive filtering, is used. Further investigation is needed to demonstrate clinical significance and pathologies.

Entities:  

Mesh:

Year:  1998        PMID: 9614744     DOI: 10.1007/bf02522853

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  The displacement cardiograph.

Authors:  R Vas; C R Joyner; D E Pittman; T C Gay
Journal:  IEEE Trans Biomed Eng       Date:  1976-01       Impact factor: 4.538

2.  Noninvasive detection of ventricular wall motion by electromagnetic coupling. Part 1. Theory: the changes in the reflected impedance of a coil over a semi-infinite medium with properties ranging from lossy dielectric to a conductor.

Authors:  M C Kwok; M G Pepper
Journal:  Med Biol Eng Comput       Date:  1991-03       Impact factor: 2.602

3.  Noninvasive detection of ventricular wall motion by electromagnetic coupling. Part 2: Experimental: cardiokymography.

Authors:  M G Pepper; D J Taylor; M C Kwok
Journal:  Med Biol Eng Comput       Date:  1991-03       Impact factor: 2.602

4.  Reconstruction of out-of-plane cardiac displacement patterns as observed on the chest wall during various phases of ECG by capacitance transducer.

Authors:  G Ramachandran; S Swarnamani; M Singh
Journal:  IEEE Trans Biomed Eng       Date:  1991-04       Impact factor: 4.538

5.  Isochronal map of chest wall vibration with cardiokymography.

Authors:  M Okada; T Nakajima; N Eizuka; Y Saitoh; M Yakata
Journal:  Comput Methods Programs Biomed       Date:  1988 Mar-Apr       Impact factor: 5.428

6.  Physical principles of the displacement cardiograph including a new device sensitive to variations in torso resistivity.

Authors:  D L Wilson; D B Geselowitz
Journal:  IEEE Trans Biomed Eng       Date:  1981-10       Impact factor: 4.538

7.  Factors determining the waveform of cardiokymography.

Authors:  Y Arai
Journal:  Jpn Heart J       Date:  1981-03

8.  Accuracy of cardiokymography during exercise testing: results of a multicenter study.

Authors:  D A Weiner
Journal:  J Am Coll Cardiol       Date:  1985-09       Impact factor: 24.094

9.  Noninvasive diagnosis of coronary artery disease: the cardiokymographic stress test.

Authors:  R A Silverberg; G A Diamond; R Vas; D Tzivoni; H J Swan; J S Forrester
Journal:  Circulation       Date:  1980-03       Impact factor: 29.690

  9 in total
  1 in total

1.  New sensor based on fibre optics for measurement of heart movement.

Authors:  K Hoeland; A Kloppe; M Hexamer; G Nowack; J Werner
Journal:  Med Biol Eng Comput       Date:  2002-09       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.