Literature DB >> 9609812

Rapid determination of glomerular filtration rate by single-bolus inulin: a comparison of estimation analyses.

C Sturgeon1, A D Sam, W R Law.   

Abstract

Rapid measurement of glomerular filtration rate (GFR) by an inulin single-bolus technique would be useful, but its accuracy has been questioned. We hypothesized that reported inaccuracies reflect the use of inappropriate mathematical models. GFR was measured in 14 intact and 5 unilaterally nephrectomized conscious male Sprague-Dawley rats (mean weight 368 +/- 12 g) by both single-bolus (25 mg/kg) and constant-infusion techniques (0.693 mg . kg-1 . min-1). The temporal decline in plasma inulin concentration was analyzed through biexponential curve fitting, which accounted for renal inulin loss before complete vascular and interstitial mixing. We compared our mathematical model based on empirical rationale with those of other investigators whose studies suggest inaccuracy of single-bolus methods. Our mathematical model yielded GFR values by single bolus that agreed with those obtained by constant infusion [slope = 0.94 +/- 0.16 (SE); y intercept = 0.23 +/- 0.64; r = 0.82]. In comparison to the data obtained by constant inulin infusion, this method yielded a very small bias of -0.0041 +/- 0.19 ml/min. Two previously reported models yielded unsatisfactory values (slope = 1. 46 +/- 0.34, y intercept = 0.47 +/- 1.5, r = 0.72; and slope = 0.17 +/- 1.26, y intercept = 17.15 +/- 5.14, r = 0.03). The biases obtained by using these methods were -2.21 +/- 0.42 and -13.90 +/- 1. 44 ml/min, respectively. The data indicate that when appropriate mathematical models are used, inulin clearance after single-bolus delivery can be used to measure GFR equivalent to that obtained by constant infusion of inulin. Attempts to use methods of analysis for simplicity or expediency can result in unacceptable measurements relative to the clinical range of values seen.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9609812     DOI: 10.1152/jappl.1998.84.6.2154

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  20 in total

1.  Measurement of glomerular filtration rate during flight in a migratory bird using a single bolus injection of FITC-inulin.

Authors:  Alexander R Gerson; Christopher G Guglielmo
Journal:  Am J Physiol Renal Physiol       Date:  2013-07-24

2.  A new mouse model of hemorrhagic shock-induced acute kidney injury.

Authors:  Lei Wang; Jiangping Song; Jacentha Buggs; Jin Wei; Shaohui Wang; Jie Zhang; Gensheng Zhang; Yan Lu; Kay-Pong Yip; Ruisheng Liu
Journal:  Am J Physiol Renal Physiol       Date:  2016-11-09

3.  Graft function assessment in mouse models of single- and dual-kidney transplantation.

Authors:  Lei Wang; Ximing Wang; Shan Jiang; Jin Wei; Jacentha Buggs; Liying Fu; Jie Zhang; Ruisheng Liu
Journal:  Am J Physiol Renal Physiol       Date:  2018-05-23

4.  A portable fiberoptic ratiometric fluorescence analyzer provides rapid point-of-care determination of glomerular filtration rate in large animals.

Authors:  Exing Wang; Daniel J Meier; Ruben M Sandoval; Vanessa E Von Hendy-Willson; Barrak M Pressler; Robert M Bunch; Mouhamad Alloosh; Michael S Sturek; George J Schwartz; Bruce A Molitoris
Journal:  Kidney Int       Date:  2011-08-31       Impact factor: 10.612

5.  Effects of different storage solutions on renal ischemia tolerance after kidney transplantation in mice.

Authors:  Lei Wang; Jin Wei; Shan Jiang; Hui-Hua Li; Liying Fu; Jie Zhang; Ruisheng Liu
Journal:  Am J Physiol Renal Physiol       Date:  2017-11-15

6.  Impaired mitochondrial complex III and melatonin responsive reactive oxygen species generation in kidney mitochondria of db/db mice.

Authors:  Hua Zhang; Hong-Mei Zhang; Li-Ping Wu; Dun-Xian Tan; Amrita Kamat; Yun-Qing Li; Michael S Katz; Hanna E Abboud; Russel J Reiter; Bin-Xian Zhang
Journal:  J Pineal Res       Date:  2011-05-27       Impact factor: 13.007

7.  Rapid diagnosis and quantification of acute kidney injury using fluorescent ratio-metric determination of glomerular filtration rate in the rat.

Authors:  Exing Wang; Ruben M Sandoval; Silvia B Campos; Bruce A Molitoris
Journal:  Am J Physiol Renal Physiol       Date:  2010-08-04

8.  Knockout of P2rx7 purinergic receptor attenuates cyst growth in a rat model of ARPKD.

Authors:  Sergey N Arkhipov; D'Anna L Potter; Aron M Geurts; Tengis S Pavlov
Journal:  Am J Physiol Renal Physiol       Date:  2019-10-21

9.  Effects of high-fat diet and losartan on renal cortical blood flow using contrast ultrasound imaging.

Authors:  Anne-Emilie Declèves; Joshua J Rychak; Dan J Smith; Kumar Sharma
Journal:  Am J Physiol Renal Physiol       Date:  2013-09-18

10.  A High-throughput method for measurement of glomerular filtration rate in conscious mice.

Authors:  Timo Rieg
Journal:  J Vis Exp       Date:  2013-05-10       Impact factor: 1.355

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.