The SimPlate Total Plate Count (TPC) test, developed by IDEXX Laboratories, Inc., detects and quantitates total bacterial concentration in food after 24 h of incubation. The performance of SimPlate TPC was compared with that of the plate count agar (PCA) method for enumerating total bacterial concentration of 255 food samples representing 15 different food matrixes. Total bacterial counts on SimPlate TPC were measured after 24 h of incubation and plotted against values obtained from PCA after 48 h. Simple regression analysis of the data showed strong correlation between the methods (r = 0.95); the sensitivity of SimPlate TPC for foodborne bacteria was 96% relative to PCA (slope = 0.96). It was concluded that SimPlate TPC is a suitable alternative for the detection and quantitation of foodborne bacteria. The method has been granted Performance Tested Certification by the AOAC Research Institute.Entities:
Mesh:
Substances:
Year: 1998 PMID: 9606922
Source DB: PubMed Journal: J AOAC Int ISSN: 1060-3271 Impact factor: 1.913