Literature DB >> 9603533

Role of the preaxillary flora in pacemaker infections: a prospective study.

A Da Costa1, H Lelièvre, G Kirkorian, M Célard, P Chevalier, F Vandenesch, J Etienne, P Touboul.   

Abstract

BACKGROUND: Infection remains a severe complication after pacemaker implantation. The purpose of our prospective study was to evaluate the role of the local bacteriologic flora in its occurrence. METHODS AND
RESULTS: Specimens were collected at the site of implantation for culture from the skin and the pocket before and after insertion in a consecutive series of patients who underwent elective permanent pacemaker implantation. Microorganisms isolated both at the time of insertion and of any potentially infective complication were compared by using conventional speciation and ribotyping. There were 103 patients (67 men and 36 women) whose age ranged from 16 to 93 years (mean+/-SD, 67+/-15). At the time of pacemaker implantation, a total of 267 isolates were identified. The majority (85%) were staphylococci. During a mean follow-up of 16.5 months (range, 1 to 24), infection occurred in four patients (3.9%). In two of them, an isolate of Staphylococcus schleiferi was recognized by molecular method as identical to the one previously found in the pacemaker pocket. In one patient, Staphylococcus aureus, an organism that was absent at the time of pacemaker insertion, was isolated. In another patient, a Staphylococcus epidermidis was identified both at the time of pacemaker insertion and when erosion occurred; however, their antibiotic resistance profiles were different.
CONCLUSIONS: This study strongly supports the hypothesis that pacemaker-related infections are mainly due to local contamination during implantation. S schleiferi appears to play an underestimated role in infectious colonization of implanted biomaterials and should be regarded as an important opportunistic pathogen.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9603533     DOI: 10.1161/01.cir.97.18.1791

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  32 in total

1.  Sterilization of skin and catheters before drawing blood cultures.

Authors:  Andreas F Widmer
Journal:  J Clin Microbiol       Date:  2003-10       Impact factor: 5.948

2.  Local symptoms at the site of pacemaker implantation indicate latent systemic infection.

Authors:  D Klug; F Wallet; D Lacroix; C Marquié; C Kouakam; S Kacet; R Courcol
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

3.  The prevalence of methicillin resistant organisms among pacemaker and defibrillator implant recipients.

Authors:  David J Rodriguez; Aisha Afzal; Rudolph Evonich; David E Haines
Journal:  Am J Cardiovasc Dis       Date:  2012-05-15

4.  A meta-analysis of antibacterial envelope use in prevention of cardiovascular implantable electronic device infection.

Authors:  Sajid Ali; Yousuf Kanjwal; Steven R Bruhl; Mohammed Alo; Mohammed Taleb; Syed S Ali; Ameer Kabour; Owais Khawaja
Journal:  Ther Adv Infect Dis       Date:  2017-05-01

5.  Management of infections involving implanted cardiac electrophysiologic devices.

Authors:  Frédéric L Paulin; Lorne J Gula; Raymond Yee; Allan C Skanes; George J Klein; Andrew D Krahn
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-09

6.  Cardiac Implantable Electronic Device Infection in Patients at Risk.

Authors:  Khaldoun G Tarakji; Christopher R Ellis; Pascal Defaye; Charles Kennergren
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-05

7.  First report of a left ventricular assist device infection caused by Staphylococcus schleiferi subspecies coagulans: a coagulase-positive organism.

Authors:  Evangeline Thibodeau; Helen Boucher; David Denofrio; Duc Thinh Pham; David Snydman
Journal:  Diagn Microbiol Infect Dis       Date:  2012-06-27       Impact factor: 2.803

8.  Sonication of explanted cardiac rhythm management devices for the diagnosis of pocket infections and asymptomatic bacterial colonization.

Authors:  Pamela K Mason; John P Dimarco; John D Ferguson; Srijoy Mahapatra; J Michael Mangrum; Kenneth C Bilchick; J Randall Moorman; Douglas E Lake; James D Bergin
Journal:  Pacing Clin Electrophysiol       Date:  2011-02       Impact factor: 1.976

9.  New perspectives of infections in cardiovascular disease.

Authors:  Ignatius W Fong
Journal:  Curr Cardiol Rev       Date:  2009-05

10.  Efficacy of a Bio-Absorbable Antibacterial Envelope to Prevent Cardiac Implantable Electronic Device Infections in High-Risk Subjects.

Authors:  Matthew J Kolek; Neel J Patel; Walter K Clair; S Patrick Whalen; Jeffrey N Rottman; Arvindh Kanagasundram; Sharon T Shen; Pablo J Saavedra; Juan C Estrada; Robert L Abraham; Christopher R Ellis
Journal:  J Cardiovasc Electrophysiol       Date:  2015-09-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.