Literature DB >> 9599579

Determination of cannabinoids in water and human saliva by solid-phase microextraction and quadrupole ion trap gas chromatography/mass spectrometry.

B J Hall1, M Satterfield-Doerr, A R Parikh, J S Brodbelt.   

Abstract

Solid-phase microextraction (SPME) is applied to the determination of cannabidiol, delta 8-tetrahydrocannabinol (delta 8-THC), delta 9-tetrahydrocannabinol (delta 9-THC), and cannabinol in pure water and human saliva. The inherent extraction behavior of the cannabinoids in pure water is evaluated along with optimization of the method in human saliva. The commercially available poly(dimethylsiloxane) (PDMS) SPME fibers were found to be the best class for the cannabinoid analysis. Partition coefficients were found to be extremely large for all of the cannabinoids (log K > 4.0). Equilibrium times for the 7- and 30-micron PDMS fibers were 50 and 240 min, respectively. A shorter extraction time of 10 min with the 30-micron PDMS fiber may be used for multiple extractions from the same vial, thus conserving the sample necessary for analysis and speeding up the total analysis time. Recoveries for the cannabinoids in saliva, relative to pure water, were dramatically improved by a method developed in our laboratory involving addition of glacial acetic acid to the sample vial prior to performing SPME. Using this method, recoveries relative to SPME in pure water ranged from 21 to 47% depending on the cannabinoid. The linear range for spiked saliva samples was established at 5-500 ng/mL (r2 > 0.994) with precisions between 11 and 20% RSD. The ultimate level of detection by SPME for the cannabinoids in saliva was 1.0 ng/mL, with signal-to-noise values of > or = 12. A saliva sample collected 30 min after marijuana smoking was subject to SPME and traditional liquid-liquid extraction analysis. Internal standard quantitation results for delta 9-THC by both methods yielded comparable results, indicating that the SPME method of analysis is highly accurate and precise. The level of delta 9-THC by SPME was found to be 9.54 ng/mL for the saliva sample.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9599579     DOI: 10.1021/ac971228g

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

Review 1.  Human cannabinoid pharmacokinetics.

Authors:  Marilyn A Huestis
Journal:  Chem Biodivers       Date:  2007-08       Impact factor: 2.408

Review 2.  Saliva as a matrix for human biomonitoring in occupational and environmental medicine.

Authors:  Bernhard Michalke; Bernd Rossbach; Thomas Göen; Anja Schäferhenrich; Gerhard Scherer
Journal:  Int Arch Occup Environ Health       Date:  2014-03-12       Impact factor: 3.015

Review 3.  Current knowledge on cannabinoids in oral fluid.

Authors:  Dayong Lee; Marilyn A Huestis
Journal:  Drug Test Anal       Date:  2013-08-25       Impact factor: 3.345

Review 4.  Cannabis and Its Secondary Metabolites: Their Use as Therapeutic Drugs, Toxicological Aspects, and Analytical Determination.

Authors:  Joana Gonçalves; Tiago Rosado; Sofia Soares; Ana Y Simão; Débora Caramelo; Ângelo Luís; Nicolás Fernández; Mário Barroso; Eugenia Gallardo; Ana Paula Duarte
Journal:  Medicines (Basel)       Date:  2019-02-23

5.  An innovative electrochemical immuno-platform towards ultra-sensitive monitoring of 2-arachidonoyl glycerol in samples from rats with sleep deprivation: bioanalysis of endogenous cannabinoids using biosensor technology.

Authors:  Fereshteh Kohansal; Ahmad Mobed; Rana Ansari; Mohammad Hasanzadeh; Ali Ahmadalipour; Nasrin Shadjou
Journal:  RSC Adv       Date:  2022-05-11       Impact factor: 4.036

6.  Spatially resolved sampling for untargeted metabolomics: A new tool for salivomics.

Authors:  Alessio Ciurli; Maximiliam Liebl; Rico J E Derks; Jacques J C Neefjes; Martin Giera
Journal:  iScience       Date:  2021-06-24
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.