Literature DB >> 9597731

A piezoelectric quartz crystal sensor for the determination of coagulation time in plasma and whole blood.

T J Cheng1, H C Chang, T M Lin.   

Abstract

A Peizoelectric Quartz Crystal (PQC) system possessing an adequate sensitivity to a slight viscosity change is employed to monitor the blood coagulation. In the case of an anticoagulated plasma specimen, prothrombin time (PT) was determined by the PQC sensor on the basis of the introduction of tissue thromboplastin (TF) and calcium ion. Discussing the PQC data statistically, we found that at 90% of the total frequency shift (delta f) the best linear relationship in a double-logarithmic plot of PT versus TF concentration in the range of 5.466-22.311 unit/ml is shown. The PQC result was compared with commercial optical coagulometry and showed a good linear correlation (ca. 0.98). The clotting and recalcification of whole blood were also studied by the PQC system. The testing time for one measurement could be completed within 20 min. and had a good agreement with that obtained conventionally.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9597731     DOI: 10.1016/s0956-5663(97)00111-5

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Assessing blood coagulation status with laser speckle rheology.

Authors:  Markandey M Tripathi; Zeinab Hajjarian; Elizabeth M Van Cott; Seemantini K Nadkarni
Journal:  Biomed Opt Express       Date:  2014-02-24       Impact factor: 3.732

2.  Blood Coagulation Testing Smartphone Platform Using Quartz Crystal Microbalance Dissipation Method.

Authors:  Jia Yao; Bin Feng; Zhiqi Zhang; Chuanyu Li; Wei Zhang; Zhen Guo; Heming Zhao; Lianqun Zhou
Journal:  Sensors (Basel)       Date:  2018-09-13       Impact factor: 3.576

Review 3.  Technology Advancements in Blood Coagulation Measurements for Point-of-Care Diagnostic Testing.

Authors:  Mohammad Mohammadi Aria; Ahmet Erten; Ozlem Yalcin
Journal:  Front Bioeng Biotechnol       Date:  2019-12-11

4.  Detection of fibrinogen and coagulation factor VIII in plasma by a quartz crystal microbalance biosensor.

Authors:  Chunyan Yao; Ling Qu; Weiling Fu
Journal:  Sensors (Basel)       Date:  2013-05-24       Impact factor: 3.576

5.  Adenosine diphosphate-decorated chitosan nanoparticles shorten blood clotting times, influencing the structures and varying the mechanical properties of the clots.

Authors:  Tze-Wen Chung; Pei-Yi Lin; Shoei-Shen Wang; Yen-Fung Chen
Journal:  Int J Nanomedicine       Date:  2014-03-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.