Comparison of four techniques for monitoring the setting kinetics of gypsum.

M M Winkler1, P Monaghan, J L Gilbert, E P Lautenschlager.   

Abstract

STATEMENT OF PROBLEM: Setting time of gypsum depends on the method of measurement.
PURPOSE: In this study, four methods for ascertaining the setting time of gypsum were compared.
MATERIAL AND METHODS: Gypsum setting was evaluated with Gillmore needles, setting expansion, scanning electron microscopy, and x-ray diffraction. Both die stone (Vel-Mix) and fast-setting dental stone (Snap-Stone) were investigated. By using Gillmore needles, both initial set and final set were recorded. Setting expansion was monitored until equilibrium was achieved. For scanning electron microscopy, samples of mixed stone were immersed into liquid nitrogen to stop the reaction. The water was subsequently removed by freeze-drying. Samples were then examined in a scanning electron microscope. For x-ray diffraction, the percentages of dihydrate and hemihydrate crystals were monitored every 1.5 minutes.
RESULTS: Setting times for the fast-setting type III stone and for the regular-setting type IV stone were approximately 3 and 10 minutes, respectively, with the Gillmore needle indentation tests; 10 and 20 minutes with scanning electron microscopy; and 20 and 60 minutes with x-ray diffraction.
CONCLUSION: Scanning electron microscopy, setting expansion, and x-ray diffraction indicated changes that occurred at times after a clinically relevant set was obtained in the gypsum setting reaction.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9597606     DOI: 10.1016/s0022-3913(98)70174-x

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  A kinetic and mechanistic study into the transformation of calcium sulfate hemihydrate to dihydrate.

Authors:  Sebastian J Gurgul; Gabriel Seng; Gareth R Williams
Journal:  J Synchrotron Radiat       Date:  2019-04-05       Impact factor: 2.616

2.  Mechanical and Non-Destructive Testing of Plasterboards Subjected to a Hydration Process.

Authors:  Zbigniew Ranachowski; Przemysław Ranachowski; Tomasz Dębowski; Adam Brodecki; Mateusz Kopec; Maciej Roskosz; Krzysztof Fryczowski; Mateusz Szymków; Ewa Krawczyk; Krzysztof Schabowicz
Journal:  Materials (Basel)       Date:  2020-05-23       Impact factor: 3.623

3.  In vitro evaluation of the precision of working casts for implant-supported restoration with multiple abutments.

Authors:  Anderson Almeida Castilho; Alberto Noriyuki Kojima; Sarina Maciel Braga Pereira; Diego Klee de Vasconcellos; Marcos Koiti Itinoche; Renata Faria; Marco Antonio Bottino
Journal:  J Appl Oral Sci       Date:  2007-06       Impact factor: 2.698

4.  Accuracy of fit of implant-supported bars fabricated on definitive casts made by different dental stones.

Authors:  Ioannis Kioleoglou; Argirios Pissiotis; Michalakis Konstantinos
Journal:  J Clin Exp Dent       Date:  2018-03-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.