Literature DB >> 9592788

Analysis of cerebrovascular diseases by a new 3-dimensional computerised X-ray angiography system.

J F Heautot1, E Chabert, Y Gandon, S Croci, R Romeas, R Campagnolo, B Chereul, J M Scarabin, M Carsin.   

Abstract

We set out to validate the concept of three-dimensional (3D) angiography. We evaluated the sensitivity and the quality of morphological analysis mode possible by an experimental system for imaging cerebrovascular disease versus standard digital subtraction angiography (DSA). The system, the 3D Morphometer, is a computerised X-ray angiography unit capable of acquiring a set of two-dimensional (2D) projections during a rotation and then reconstructing a 3D volume from them. We studied 78 patients with suspected cerebrovascular disease. 3D and 2D images (standard 2D DSA performed during the same procedure), were reviewed blindly to assess detection and display of morphological characteristics of cerebrovascular diseases. We found 53 aneurysms, 22 arteriovenous malformations and two venous angiomas. On 3D angiography we detected two aneurysms we missed on 2D angiography. In 47 aneurysms on which further data were obtained during surgery or embolisation, the 3D angiography allowed more accurate analysis of the neck and surrounding vessels in cases in which the 2D angiographic findings were doubtful. Assessment of arteriovenous malformations was equivalent with both techniques. Under the conditions of our study, the technical constraints being the same for both methods, 3D angiography was superior to 2D angiography. Implementation on C-arm vascular systems is being evaluated.

Entities:  

Mesh:

Year:  1998        PMID: 9592788     DOI: 10.1007/s002340050568

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  12 in total

1.  In vitro evaluation of 2D-digital subtraction angiography versus 3D-time-of-flight in assessment of intracranial cerebral aneurysm filling after endovascular therapy.

Authors:  V Costalat; E Lebars; L Sarry; A Defasque; E Barbotte; H Brunel; G Bourbotte; A Bonafé
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

Review 2.  How Can New Imaging Modalities Help in the Practice of Radiology?

Authors:  Berhan Pirimoglu; Recep Sade; Hayri Ogul; Mecit Kantarci; Suat Eren; Akın Levent
Journal:  Eurasian J Med       Date:  2016-10

3.  Volume-of-change cone-beam CT for image-guided surgery.

Authors:  Junghoon Lee; J Webster Stayman; Yoshito Otake; Sebastian Schafer; Wojciech Zbijewski; A Jay Khanna; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2012-07-17       Impact factor: 3.609

4.  Simultaneous Bilateral Vertebral Artery 3D Rotational Angiography. Technical Report of Two Cases.

Authors:  J F Reavey-Cantwell; S B Lewis; C Firment
Journal:  Interv Neuroradiol       Date:  2005-10-26       Impact factor: 1.610

5.  Comparison of 2D and 3D digital subtraction angiography in evaluation of intracranial aneurysms.

Authors:  Takeshi Sugahara; Yukunori Korogi; Kouji Nakashima; Satoshi Hamatake; Shin Honda; Mutsumasa Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2002-10       Impact factor: 3.825

6.  Three-dimensional rotation venography using the digital subtraction angiography unit with a flat-panel detector: usefulness for the transtemporal/transtentorial approaches.

Authors:  A Nishio; T Takami; K Ohata; M Hara; Y Mitsuhashi; H Yokote; Y Inoue; M Hosogai; T Ichida; S Ikeda
Journal:  Neuroradiology       Date:  2004-10-20       Impact factor: 2.804

7.  Clinical benefits of rotational 3D angiography in endovascular treatment of ruptured cerebral aneurysm.

Authors:  Toshi Abe; Masaru Hirohata; Norimitsu Tanaka; Yusuke Uchiyama; Kazuyuki Kojima; Kiminori Fujimoto; Alexander M Norbash; Naofumi Hayabuchi
Journal:  AJNR Am J Neuroradiol       Date:  2002-04       Impact factor: 3.825

8.  Anatomic features predictive of complete aneurysm occlusion can be determined with three-dimensional digital subtraction angiography.

Authors:  Hiro Kiyosue; Shuichi Tanoue; Mika Okahara; Yuzo Hori; Takaharu Nakamura; Hirofumi Nagatomi; Hiromu Mori
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

9.  Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms.

Authors:  Albrecht Hochmuth; Uwe Spetzger; Martin Schumacher
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

10.  Clinical usefulness of unsubtracted 3D digital angiography compared with rotational digital angiography in the pretreatment evaluation of intracranial aneurysms.

Authors:  Toshinori Hirai; Yukunori Korogi; Kenji Suginohara; Ken Ono; Tomohiro Nishi; Shozaburo Uemura; Masayuki Yamura; Yasuyuki Yamashita
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.