Literature DB >> 9592001

Postreduction computed tomography in developmental dislocation of the hip: part I: analysis of measurement reliability.

B G Smith1, J R Kasser, L A Hey, D Jaramillo, M B Millis.   

Abstract

Twenty computed tomographic (CT) scans of infants in spica casts after closed or open reduction for developmental hip dislocation (DDH) were analyzed for intra- and interrater reliability. Ten measurements of infant hip anatomy were assessed by three raters by using standard statistical analysis. All six measurements of acetabular anteversion and lateral or posterior displacement of the femoral metaphysis from the acetabulum or from a modified Shenton's line drawn from the pubic rami demonstrated both intra- and interrater reliability. All four measurements of acetabular structure could not be reliably measured either within or between observers. We also introduced a new measurement based on the principle of Shenton's line to aid in the assessment of femoral-head location after reduction in patients with DDH; this was reliably determined both within and among observers.

Entities:  

Mesh:

Year:  1997        PMID: 9592001     DOI: 10.1097/00004694-199709000-00010

Source DB:  PubMed          Journal:  J Pediatr Orthop        ISSN: 0271-6798            Impact factor:   2.324


  13 in total

Review 1.  Imaging in the surgical management of developmental dislocation of the hip.

Authors:  Leslie Grissom; H T Harcke; Mihir Thacker
Journal:  Clin Orthop Relat Res       Date:  2008-02-21       Impact factor: 4.176

2.  Determination of hip reduction in spica cast treatment for DDH: a comparison of radiography and ultrasound.

Authors:  Oliver Eberhardt; Michael Zieger; Michael Langendoerfer; Thomas Wirth; Francisco F Fernandez
Journal:  J Child Orthop       Date:  2009-08-06       Impact factor: 1.548

Review 3.  Developmental dysplasia of the hip: What has changed in the last 20 years?

Authors:  Pavel Kotlarsky; Reuben Haber; Victor Bialik; Mark Eidelman
Journal:  World J Orthop       Date:  2015-12-18

4.  Clinical study of anterior hip ultrasound (van Douveren's method)-assisted Pavlik harness.

Authors:  Yihua Ge; Zhigang Wang; Yunlan Xu
Journal:  Int Orthop       Date:  2018-08-16       Impact factor: 3.075

5.  Does Perfusion MRI After Closed Reduction of Developmental Dysplasia of the Hip Reduce the Incidence of Avascular Necrosis?

Authors:  Alex L Gornitzky; Andrew G Georgiadis; Mark A Seeley; B David Horn; Wudbhav N Sankar
Journal:  Clin Orthop Relat Res       Date:  2016-05       Impact factor: 4.176

6.  A study on the complications of surgical treatment for bilateral developmental dysplasia of the hip and a comparison of two osteotomy techniques.

Authors:  Naci Ezirmik; Kadri Yildiz
Journal:  Eurasian J Med       Date:  2011-12

7.  Anterior hip ultrasound: A useful technique in developmental dysplasia of the hips.

Authors:  Margaret A Taylor; James Gb Maclean
Journal:  Ultrasound       Date:  2020-11-09

8.  Point of Care Ultrasound as Performed by the Clinician for the Enhancement of Physical Examination: A Technique Guide for Developmental Hip Dysplasia.

Authors:  Christina Herrero; Neha Jejurikar; Ajay Kanakalamedala; Yhan Colon Iban; Pablo Castañeda
Journal:  Indian J Orthop       Date:  2021-11-21       Impact factor: 1.033

9.  Three-dimensional computed tomography analysis and anteversion study after periacetabular osteotomy of pelvis in children.

Authors:  Roger Jawish; Rami Khalife; Jacques Ghorayeb
Journal:  J Child Orthop       Date:  2007-11-17       Impact factor: 1.548

10.  A novel method for assessing postoperative femoral head reduction in developmental dysplasia of the hip.

Authors:  Anthony Cooper; Owain Evans; Farhan Ali; Mark Flowers
Journal:  J Child Orthop       Date:  2014-07-04       Impact factor: 1.548

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.