Literature DB >> 9590484

Determinants of reproducibility of lung function tests in children aged 7 to 10 years.

M Studnicka1, T Frischer, M Neumann.   

Abstract

Lung function (LF) tests are part of many investigations in childhood lung disease. However, individual reproducibility of LF will confound between-subject differences. At the same time, increased LF variability has been linked to respiratory disease. In a sample of 598 children, two LF tests, separated by a 5-min interval, were recorded, and reliability (Rel) of forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), and maximal expiratory flow at 50% of FVC (MEF50) was determined. Rel was also assessed in children trained and untrained in the performance of LF. To investigate determinants of reproducibility for FEV1, the absolute difference between two repeated tests was calculated. Whenever this difference was > 120 ml, a child was considered to demonstrate excessive variability (poor reproducibility) in FEV1. For volume parameters coefficients of reliability (Crel) were found to be better than for MEF50 (FEV1: 0.96; FVC: 0.94, MEF50: 0.91). In untrained children Crel for FEV1 was only 0.91, but it was increased in subsequent visits (0.98, 0.97, and 0.97 at the second, third, and fourth tests, respectively). Excessive variability in FEV1 was observed in 10% of children and was related to the presence of wheeze [odds ratio (OR) 6.31; 95% confidence interval (CI) 1.78-22.4), shortness of breath (OR 3.14; 95% CI 1.00-9.93), a diagnosis of asthma (OR 6.25; 95% CI 1.76-22.1), and bronchial hyperresponsiveness (OR 4.30; 95% CI 2.07-8.94). We conclude that increased variability of LF is likely to be present in young children not accustomed to the testing procedure and in children with respiratory symptoms. Therefore, before guidelines for LF testing are applied, children should be trained to perform the tests and we should be cautious in the interpretation of test results in children who present with symptoms.

Entities:  

Mesh:

Year:  1998        PMID: 9590484     DOI: 10.1002/(sici)1099-0496(199804)25:4<238::aid-ppul4>3.0.co;2-g

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  6 in total

1.  The quality of home spirometry in school children with asthma.

Authors:  D C Wensley; M Silverman
Journal:  Thorax       Date:  2001-03       Impact factor: 9.139

2.  Early wheeze as reported by mothers and lung function in 4-year-olds. Prospective cohort study in Krakow.

Authors:  Wieslaw Jedrychowski; Umberto Maugeri; Frederica P Perera; Elzbieta Mroz; Maria Klimaszewska-Rembiasz; Elzbieta Flak; Susan Edwards; Renata Majewska; Agata Sowa
Journal:  Pediatr Pulmonol       Date:  2010-09

3.  Reference values of interrupter respiratory resistance in healthy preschool white children.

Authors:  E Lombardi; P D Sly; G Concutelli; E Novembre; G Veneruso; G Frongia; R Bernardini; A Vierucci
Journal:  Thorax       Date:  2001-09       Impact factor: 9.139

4.  Feasibility of measuring lung function in preschool children.

Authors:  W Nystad; S O Samuelsen; P Nafstad; E Edvardsen; T Stensrud; J J K Jaakkola
Journal:  Thorax       Date:  2002-12       Impact factor: 9.139

5.  Relating small airways to asthma control by using impulse oscillometry in children.

Authors:  Yixin Shi; Anna S Aledia; Ahramahzd V Tatavoosian; Shruthi Vijayalakshmi; Stanley P Galant; Steven C George
Journal:  J Allergy Clin Immunol       Date:  2011-12-17       Impact factor: 10.793

6.  The practical application and interpretation of simple lung function tests in cystic fibrosis.

Authors:  P L Brand; C K van der Ent
Journal:  J R Soc Med       Date:  1999       Impact factor: 18.000

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.