Literature DB >> 9587286

Dimensional stability of thermosensitive gutta-percha.

C Q Lee1, Y Chang, C M Cobb, S Robinson, E M Hellmuth.   

Abstract

The expansion and shrinkage of four commercial brands of endodontic thermosensitive gutta-percha were evaluated. A modified volume dilatometry technique was used; the dilatometric system (DS) consisted of Pyrex glass capillary tubes and a specimen chamber. Each sample was weighed to 10(-4) mg, placed in the specimen chamber, and subjected to vacuum for 45 min to eliminate moisture or gases. The DS was gradually heated from 24 degrees C to 80 degrees C and then cooled to 24 degrees C using a well-agitated temperature-controlled water bath. In a parallel set of experiments, the DS was heated in the same manner but cooled to body temperature (37 degrees C) in the water bath and the temperature kept stable at 37 degrees C for 24 h. The level of the mercury meniscus within the DS was monitored to determine the percent volume change of each sample at 2 degrees C intervals. All samples expanded as the temperature was elevated and shrank during cooling. The percent volume change for each of the four gutta-percha products, as the temperature was raised to 80 degrees C, ranged from an expansion of +11.62 to +12.25. As the temperature was lowered from 80 degrees C to 24 degrees C, the percent volume change representing shrinkage ranged from -2.22 to -3.53. When the temperature was lowered from 80 degrees C to 37 degrees C, the products continued to exhibit shrinkage for a range of time between 45 min and 10 h before stabilizing at a fixed volume. The final percent volume change for each experiment, with each product, was positive, ranging from +5.50 to +7.20, with discernible differences between products.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9587286     DOI: 10.1016/S0099-2399(06)81126-X

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  3 in total

1.  Thermal analysis and stability of commercially available endodontic obturation materials.

Authors:  H W Roberts; T C Kirkpatrick; B E Bergeron
Journal:  Clin Oral Investig       Date:  2017-02-10       Impact factor: 3.573

Review 2.  Advances in endodontics: Potential applications in clinical practice.

Authors:  Anil Kishen; Ove A Peters; Matthias Zehnder; Anibal R Diogenes; Madhu K Nair
Journal:  J Conserv Dent       Date:  2016 May-Jun

Review 3.  Bioactive-glass in Endodontic Therapy and Associated Microsurgery.

Authors:  Andrea Corrado Profeta; Gian Marco Prucher
Journal:  Open Dent J       Date:  2017-03-31