Cardiac arrhythmias with external fixed-rate signal generators in shock wave lithotripsy with the Medstone lithotripter.

J P Ganem1, C C Carson.   

Abstract

OBJECTIVES: To evaluate the incidence and outcome of cardiac arrhythmias associated with an external fixed-rate generator and the Medstone lithotripter with regard to stone location, anesthesia type, patient age, and gender.
METHODS: Data were obtained on 933 patients who underwent shock wave lithotripsy (SWL) with the Medstone lithotripter. Patients were randomly divided into two study groups, including those with pre-existing cardiac disease, hypertension, and cardiac medications. Group 1 (576 patients) were treated with the external fixed-rate signal generator (cardiac simulator). Group 2 (357 patients) underwent electrocardiogram-gated SWL (no simulator). All patients were monitored for arrhythmias during SWL. Patients who developed arrhythmias on the simulator were converted to gated SWL.
RESULTS: In group 1, 463 patients (80%) had no arrhythmias during treatment, whereas 113 patients (20%) developed cardiac arrhythmias (primarily premature ventricular contractions [PVCs]) and were successfully converted to gated SWL. Only 1 patient in group 2 (0.3%) had a documented arrhythmia (PVC). Group 1 patients who developed arrhythmias with a cardiac simulator were more likely to have renal rather than ureteral stones. Chi-square analysis showed a significant correlation between patients with and without arrhythmias in group 1 with regard to stone location (P <0.0001). In group 1, regional anesthesia, intravenous anesthesia, and general anesthesia had an arrhythmia rate of 14%, 27%, and 38%, respectively. The only patient in group 2 who developed arrhythmias was under general anesthesia. The differences between groups 1 and 2, with regard to anesthesia type and arrhythmia, were statistically significant (P <0.001). No patients required additional medical therapy or hospitalization for cardiac events, and all patients safely completed the SWL treatment.
CONCLUSIONS: With careful monitoring and adequate precautions, external fixed-rate signal generators are safe, effective methods for pacing the Medstone shock wave lithotripter and probably other extracorporeal shock wave lithotripters.

Entities:  

Mesh:

Year:  1998        PMID: 9586605     DOI: 10.1016/s0090-4295(97)00707-3

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  3 in total

1.  Variables influencing the likelihood of cardiac dysrhythmias during extracorporeal shock wave lithotripsy.

Authors:  Thomas A A Skinner; Richard W Norman
Journal:  Can Urol Assoc J       Date:  2011-07-04       Impact factor: 1.862

2.  Precipitation of de novo atrial fibrillation during Shockwave Intravascular Lithotripsy® after pacing capture during the treatment of proximal right coronary artery disease: a case report.

Authors:  Elizabeth Curtis; Ali Khan; Seif El-Jack; Tim Glenie
Journal:  Eur Heart J Case Rep       Date:  2019-09-27

3.  Enteral diclofenac controls pain and reduces intravenous injection during extracorporeal shock wave lithotripsy.

Authors:  Mehrdad Mesbah Kiaei; Mahmoud Reza Mohaghegh; Gholamreza Movaseghi; Masoud Ghorbanlo
Journal:  Eur J Transl Myol       Date:  2018-05-02
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.