Abstract

To evaluate the usefulness of magnetic resonance angiography (MRA) in pulmonary and mediastinal diseases, 24 cases (15 lung cancers, 2 metastatic lung tumors and 7 other diseases) were studied with the 3D FLASH (TE = 3 msec.) method. In resected cases, MRA images were compared with intraoperative findings. Twenty of 24 cases were consistent with intraoperative findings. In 4 resected cases in which the findings were inconsistent, pulmonary angiography (PAG) findings were similar to those of MRA. From these results, MRA is considered an effective and non-invasive method for evaluation of pulmonary vessels.

Entities:  

Mesh:

Year:  1998        PMID: 9584478     DOI: 10.1007/BF03217743

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  6 in total

1.  [Determination of optimal technical factors for the single breath-hold pulmonary MR angiography and its clinical applications].

Authors:  F Watanabe
Journal:  Nihon Igaku Hoshasen Gakkai Zasshi       Date:  1996-06

2.  Adverse reactions to ionic and nonionic contrast media. A report from the Japanese Committee on the Safety of Contrast Media.

Authors:  H Katayama; K Yamaguchi; T Kozuka; T Takashima; P Seez; K Matsuura
Journal:  Radiology       Date:  1990-06       Impact factor: 11.105

3.  [Contrast-enhanced 3D MR angiography of the chest and abdomen with breath-holding using phase reordering].

Authors:  M Amanuma; E Sugimoto; H Hirata; K Enomoto; T Watabe; T Kimura; O Takizawa; A Heshiki
Journal:  Nihon Igaku Hoshasen Gakkai Zasshi       Date:  1995-07

4.  [Breath-holding three-dimensional MR imaging: evaluation of phase reordering for motion artifact suppression].

Authors:  M Amanuma; T Kimura; O Takizawa; E Kozawa; K Enomoto; T Watabe; A Heshiki
Journal:  Nihon Igaku Hoshasen Gakkai Zasshi       Date:  1995-03

5.  [Distal pulmonary vessels demonstration by magnetic resonance angiography and its usefulness in the diagnosis of peripheral nodules].

Authors:  H Fukuda; K Awai; T Suzuki; S Nakamura; K Fujikawa
Journal:  Nihon Igaku Hoshasen Gakkai Zasshi       Date:  1995-10

6.  Clinical safety of gadopentetate dimeglumine.

Authors:  K L Nelson; L M Gifford; C Lauber-Huber; C A Gross; T A Lasser
Journal:  Radiology       Date:  1995-08       Impact factor: 11.105