Proximal and distal femoral centralizers in modern cemented hip arthroplasty.

B A Goldberg1, G al-Habbal, P C Noble, M Paravic, T R Liebs, H S Tullos.   

Abstract

Third generation cementing techniques using intramedullary restrictors, low porosity cement with pressurization, lavage, and cement-stem bond enhancement do not prevent implant malalignment and inadequate cement mantle thickness. This has led to the development of modular proximal and distal centralizers to control the alignment of the femoral component and maintain an adequate thickness of the cement, thereby theoretically decreasing the rate of aseptic loosening. A retrospective analysis was performed of 100 primary cemented centralized femoral components. At an average followup of 5.7 years (range, 4-8 years), the average Harris Hip Score was 90. There were no cases of aseptic loosening, osteolysis, or impending failure. Ninety-one percent of femoral stems were implanted with satisfactory alignment with an optimal cement thickness. However, six distal centralizers and one proximal centralizer fractured at the time of insertion and voids frequently were seen in and around the distal centralizer. Although centralizers improve prosthesis alignment and cement mantle thickness, the long term effects of centralizer fracture and distal cement voids need to be observed to determine if centralizers improve previous implant survival.

Entities:  

Mesh:

Year:  1998        PMID: 9584379     DOI: 10.1097/00003086-199804000-00020

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  4 in total

1.  Comparison of distal and proximal centralising devices in hip arthroplasty.

Authors:  N Aydin; M Bezer; A H Akgulle; B Saygi; B Kocaoğlu; O Guven
Journal:  Int Orthop       Date:  2008-08-19       Impact factor: 3.075

2.  Cementation technique for elbow arthroplasty; an international survey.

Authors:  Tariq A Kwaees; Rohit Singhal; Denise Eygendaal; Charalambos P Charalambous
Journal:  J Orthop       Date:  2019-07-01

3.  No benefit of a proximal stem centralizer in cementing of a femoral prosthesis in human cadavers.

Authors:  Juozas Petruskevicius; Thomas Lind-Hansen; Ramune Aleksyniene; Jens R Nyengaard; Poul T Nielsen; Kjeld Søballe
Journal:  Acta Orthop       Date:  2011-03-24       Impact factor: 3.717

4.  Importance of a distal centralizer in experimental malpositioning of cemented stems. A biomechanical study on human femora.

Authors:  Andreas Kusserow; Andreas Ficklscherer; Peter Cornelius Kreuz; Susanne Finze; Wolfram Mittelmeier; Volkmar Jansson; Stefan Milz; Bernd Wegener
Journal:  Arch Med Sci       Date:  2015-12-11       Impact factor: 3.318

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.