Literature DB >> 9581410

In vivo horizontal bending moments on implants.

E J Richter1.   

Abstract

To date, transverse and vertical forces applied eccentrically to the axis of dental implants in the molar area during oral function have not been quantified. A specially designed load cell placed directly in the implant allowed for measurements of bending moments. Results of both load directions were compared to each other and to the loads applied vertically along the implant axis. The stress in the bone-implant interface area caused by these three different types of loads was calculated by finite element analysis. The transverse loads during chewing resulted in the highest bending moments (170 Nmm mean maximum) and the highest stress in the bone (sigma max approximately 6.2 MPa) at the crest to the buccal side. Mesial implant moment was significantly less (52 Nmm mean maximum moment; sigma max approximately 1.3 MPa). Clenching in centric occlusion caused a bending moment either to the lingual or to the buccal side, depending on the occlusal contour (140 Nmm maximum).

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9581410

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  8 in total

1.  Development of 3D CAD/FEM Analysis System for Natural Teeth and Jaw Bone Constructed from X-Ray CT Images.

Authors:  Aki Hasegawa; Akikazu Shinya; Yuji Nakasone; Lippo V J Lassila; Pekka K Vallittu; Akiyoshi Shinya
Journal:  Int J Biomater       Date:  2010-07-18

2.  Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants.

Authors:  Hnd Hadi Mohammed; Jin-Han Lee; Ji-Myung Bae; Hye-Won Cho
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

3.  A three-dimensional finite element analysis of a passive and friction fit implant abutment interface and the influence of occlusal table dimension on the stress distribution pattern on the implant and surrounding bone.

Authors:  Hasan Sarfaraz; Anoopa Paulose; K Kamalakanth Shenoy; Akhter Hussain
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

4.  All-Ceramic Single Crown Restauration of Zirconia Oral Implants and Its Influence on Fracture Resistance: An Investigation in the Artificial Mouth.

Authors:  Ralf-Joachim Kohal; Jolanta Bernadette Kilian; Susanne Stampf; Benedikt Christopher Spies
Journal:  Materials (Basel)       Date:  2015-04-01       Impact factor: 3.623

5.  The Failure Envelope Concept Applied To The Bone-Dental Implant System.

Authors:  R Korabi; K Shemtov-Yona; A Dorogoy; D Rittel
Journal:  Sci Rep       Date:  2017-05-17       Impact factor: 4.379

6.  A Comparative Evaluation of the Strain Transmitted through Prostheses on Implants with Two Different Macro-Structures and Connection during Insertion and Loading Phase: An In Vitro Study.

Authors:  Riyam Kassem; Amar Samara; Ameer Biadsee; Shchada Masarwa; Tarek Mtanis; Zeev Ormianer
Journal:  Materials (Basel)       Date:  2022-07-16       Impact factor: 3.748

7.  Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis.

Authors:  Wen-Tao Zhang; Kang-Jie Cheng; Fan Yang; Lin-Hong Wang; Yun-Feng Liu; Russell Wang; Yun-Fang Chen; Yu-de Ding
Journal:  BMC Oral Health       Date:  2022-09-30       Impact factor: 3.747

8.  Evaluation of stress distribution of implant-retained mandibular overdenture with different vertical restorative spaces: A finite element analysis.

Authors:  Behnaz Ebadian; Mahmoud Farzin; Saeid Talebi; Niloufar Khodaeian
Journal:  Dent Res J (Isfahan)       Date:  2012-11
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.