Literature DB >> 9580923

Use of whole-body plethysmography to compare bronchodilator inhaler efficacy.

A H Morice1, J C Waterhouse, E M Peers, M Parry-Billings.   

Abstract

Whole-body plethysmography is not included in guidelines from regulatory authorities for the development of treatments or delivery devices for lung disease, despite its potential advantages compared to spirometry. Two separate studies were undertaken to assess the use of specific airway conductance (sGaw) as a pharmacodynamic endpoint for the comparison of two bronchodilator delivery systems (a novel dry powder inhaler and a standard metered dose inhaler). The first pilot study involved delivery of a single dose of salbutamol (200 micrograms) to 12 healthy volunteers and determination of sGaw up to 120 min after treatment. The second study involved delivery of cumulative doses of salbutamol (100, 200 and 400 micrograms) to 19 healthy volunteers with demonstrated reversibility of sGaw to the bronchodilator and measurement of sGaw up to 240 min after treatment. In both studies, increases in sGaw after treatment were significant compared to placebo and larger than the recorded increases in FEV1. Increases in sGaw were similar for both delivery devices and support the therapeutic equivalence of the two products. Power calculations indicated that the second study had appropriate statistical power to discriminate between treatments. It is concluded that the assessment of sGaw in healthy volunteers may be a useful and sensitive pharmacodynamic endpoint for use in the development of bronchodilators and their delivery devices.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9580923     DOI: 10.1159/000029242

Source DB:  PubMed          Journal:  Respiration        ISSN: 0025-7931            Impact factor:   3.580


  5 in total

Review 1.  Discriminating measures of bronchodilator drug efficacy and potency.

Authors:  H Buck; M Parry-Billings
Journal:  Br J Clin Pharmacol       Date:  2001-09       Impact factor: 4.335

2.  Quantifying bronchodilator responses in chronic obstructive pulmonary disease trials.

Authors:  Federico Lavorini
Journal:  Br J Clin Pharmacol       Date:  2005-04       Impact factor: 4.335

Review 3.  Impulse oscillometry in the evaluation of diseases of the airways in children.

Authors:  Hirsh D Komarow; Ian A Myles; Ashraf Uzzaman; Dean D Metcalfe
Journal:  Ann Allergy Asthma Immunol       Date:  2011-01-06       Impact factor: 6.347

4.  A comparison of plethysmography, spirometry and oscillometry for assessing the pulmonary effects of inhaled ipratropium bromide in healthy subjects and patients with asthma.

Authors:  C M Houghton; A A Woodcock; D Singh
Journal:  Br J Clin Pharmacol       Date:  2005-02       Impact factor: 4.335

5.  Stable to improved cardiac and pulmonary function in children with high-risk sickle cell disease following haploidentical stem cell transplantation.

Authors:  Deborah Friedman; Allen J Dozor; Jordan Milner; Marise D'Souza; Julie-An Talano; Theodore B Moore; Shalini Shenoy; Qiuhu Shi; Mark C Walters; Elliott Vichinsky; Susan K Parsons; Suzanne Braniecki; Chitti R Moorthy; Janet Ayello; Allyson Flower; Erin Morris; Harshini Mahanti; Sandra Fabricatore; Liana Klejmont; Carmella van de Ven; Lee Ann Baxter-Lowe; Mitchell S Cairo
Journal:  Bone Marrow Transplant       Date:  2021-05-06       Impact factor: 5.483

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.