Literature DB >> 9579642

PFA-100 system: a new method for assessment of platelet dysfunction.

E F Mammen1, P C Comp, R Gosselin, C Greenberg, W K Hoots, C M Kessler, E C Larkin, D Liles, D J Nugent.   

Abstract

The PFA-100 system is a platelet function analyzer designed to measure platelet-related primary hemostasis. The instrument uses two disposable cartridges: a collagen/epinephrine (CEPI) and a collagen/ADP (CADP) cartridge. Previous experience has shown that CEPI cartridges detect qualitative platelet defects, including acetylsalicylic acid (ASA)-induced abnormalities, while CADP cartridges detect only thrombocytopathies and not ASA use. In this seven-center trial, 206 healthy subjects and 176 persons with various platelet-related defects, including 127 ASA users, were studied. The platelet function status was determined by a platelet function test panel. Comparisons were made as to how well the defects were identified by the PFA-100 system and by platelet aggregometry. The reference intervals for both cartridges, testing the 206 healthy subjects, were similar to values described in smaller studies in the literature [mean closure time (CT) 132 s for CEPI and 93 s for CADP]. The use of different lot numbers of cartridges or duplicate versus singleton testing revealed no differences. Compared with the platelet function status, the PFA-100 system had a clinical sensitivity of 94.9% and a specificity of 88.8%. For aggregometry, a sensitivity of 94.3% and a specificity of 88.3% were obtained. These values are based on all 382 specimens. A separate analysis of sensitivity by type of platelet defect, ASA use versus congenital thrombocytopathies, revealed for the PFA-100 system a 94.5% sensitivity in identifying ASA users and a 95.9% sensitivity in identifying the other defects. For aggregometry, the values were 100% for ASA users and 79.6% for congenital defects. Analysis of concordance between the PFA-100 system and aggregometry revealed no difference in clinical sensitivity and specificity between the systems (p > 0.9999). The overall agreement was 87.5%, with a Kappa index of 0.751. The two tests are thus equivalent in their ability to identify normal and abnormal platelet defects. Testing 126 subjects who took 325 mg ASA revealed that the PFA-100 system (CEPI) was able to detect 71.7% of ASA-induced defects with a positive predictive value of 97.8%. The overall clinical accuracy of the system, calculated from the area under the ROC curve, was 0.977. The data suggest that the PFA-100 system is highly accurate in discriminating normal from abnormal platelet function. The ease of operation of the instrument makes it a useful tool to use in screening patients for platelet-related hemostasis defects.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9579642     DOI: 10.1055/s-2007-995840

Source DB:  PubMed          Journal:  Semin Thromb Hemost        ISSN: 0094-6176            Impact factor:   4.180


  39 in total

Review 1.  Applications of anti-platelet monitoring in catheterization laboratory.

Authors:  D Mukherjee; D J Moliterno
Journal:  J Thromb Thrombolysis       Date:  2000-04       Impact factor: 2.300

2.  In vitro bleeding test with PFA-100-aspects of controlling individual acetylsalicylic acid induced platelet inhibition in patients with cardiovascular disease.

Authors:  A J Peters; M Borries; F Gradaus; T W Jax; F C Schoebel; B E Strauer
Journal:  J Thromb Thrombolysis       Date:  2001-12       Impact factor: 2.300

3.  Coronary angioplasty enhances platelet reactivity through von Willebrand factor release.

Authors:  D A Gorog; H Douglas; N Ahmed; D C Lefroy; G J Davies
Journal:  Heart       Date:  2003-03       Impact factor: 5.994

4.  The effect of glycoprotein IIIa PIA 1/A2 polymorphism on the PFA-100 response to GP IIb IIa receptor inhibitors-the importance of anticoagulants used.

Authors:  Katriina Aalto-Setälä; Pekka J Karhunen; Jussi Mikkelsson; Kari Niemelä
Journal:  J Thromb Thrombolysis       Date:  2005-08       Impact factor: 2.300

5.  Inhibition of platelet function by abciximab or high-dose tirofiban in patients with STEMI undergoing primary PCI: a randomised trial.

Authors:  J W van Werkum; W B M Gerritsen; J C Kelder; C M Hackeng; S M Ernst; V H M Deneer; M J Suttorp; B J W M Rensing; H W M Plokker; J M Ten Berg
Journal:  Neth Heart J       Date:  2007       Impact factor: 2.380

6.  Antiplatelet Effect of Sequential Administration of Cilostazol in Patients with Acetylsalycilic Acid Resistance.

Authors:  Muzaffer Cakmak; Bora Demircelik; Mustafa Cetin; Zehra Cetin; Serhat Isık; Hulya Cıcekcıoglu; Feridun Vasfi Ulusoy; Beyhan Eryonucu
Journal:  Acta Cardiol Sin       Date:  2016-05       Impact factor: 2.672

7.  Effects of persistent platelet reactivity despite aspirin therapy on cardiac troponin I and creatine kinase-MB levels after elective percutaneous coronary interventions.

Authors:  Oyku Gulmez; Aylin Yildirir; Gamze Kaynar; Didem Konas; Alp Aydinalp; Cagatay Ertan; Bulent Ozin; Haldun Muderrisoglu
Journal:  J Thromb Thrombolysis       Date:  2007-06-16       Impact factor: 2.300

8.  Comparative efficacy of in vitro and in vivo metabolized aspirin in the DeBakey ventricular assist device.

Authors:  Jawaad Sheriff; Gaurav Girdhar; Wei-Che Chiu; Jolyon Jesty; Marvin J Slepian; Danny Bluestein
Journal:  J Thromb Thrombolysis       Date:  2014-05       Impact factor: 2.300

9.  Interaction of clopidogrel and statins in secondary prevention after cerebral ischaemia - a randomized, double-blind, double-dummy crossover study.

Authors:  Timo Siepmann; Denise Heinke; Jessica Kepplinger; Kristian Barlinn; Siegmund Gehrisch; Xina Grählert; Uta Schwanebeck; Heinz Reichmann; Volker Puetz; Ulf Bodechtel; Georg Gahn
Journal:  Br J Clin Pharmacol       Date:  2014-11       Impact factor: 4.335

10.  Aspirin resistance.

Authors:  Khaled Mansour; Ali T Taher; Khaled M Musallam; Samir Alam
Journal:  Adv Hematol       Date:  2009-04-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.