Literature DB >> 9579265

Intubation via the LMA using a Cook retrograde intubation kit.

G A Arndt1, J Topp, J Hannah, T S McDowell, A Lesko.   

Abstract

PURPOSE: We report two cases of difficult intubation where a laryngeal mask airway (LMA) was used and changed to a conventional endotracheal tube using a retrograde intubation set. CLINICAL
FINDINGS: In two patients, following induction of anaesthesia, the trachea could not be intubated in the conventional fashion with a blade. In both patients an LMA was inserted to achieve an airway. In both patients intubation with a conventional endotracheal tube was required. A Cook Retrograde Intubation Kit and fibreoptic bronchoscope were used to change the LMA to conventional endotracheal tube without problems.
CONCLUSION: The Cook retrograde intubation allows an LMA to be replaced with an endotracheal tube with an ID greater than 6 mm with a #3 or 7 mm with a #5 LMA. This technique places an exchange stylet into the airway which is superior to a conventional guidewire. This method allows the airway to be maintained until the LMA is exchanged with an endotracheal tube. Anaesthesia may be maintained and the airway instrumented without difficulty using this technique.

Entities:  

Mesh:

Year:  1998        PMID: 9579265     DOI: 10.1007/BF03012912

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  8 in total

1.  [Intubation with a tube exchanger on an intubation trainer. Influence of tube tip position on successful intubation].

Authors:  M Kemper; T Haas; S Imach; M Weiss
Journal:  Anaesthesist       Date:  2014-07-02       Impact factor: 1.041

2.  Wire-guided (Seldinger technique) intubation through a face mask in urgent, difficult and grossly distorted airways.

Authors:  Jake M Heier; Kristopher M Schroeder; Richard E Galgon; George A Arndt
Journal:  Saudi J Anaesth       Date:  2012-07

3.  Is central-line guidewire sufficient for retrograde intubation?

Authors:  Harihar V Hegde; P Raghavendra Rao; Shrirang V Torgal
Journal:  Indian J Anaesth       Date:  2011-05

4.  Innovative management of difficult paediatric airway, using antegrade seldinger technique.

Authors:  Anuj Jain; Vaishali Waindeskar; Mohan Nema
Journal:  Indian J Anaesth       Date:  2019-07

5.  Successful wire-guided fiberoptic nasotracheal intubation in a patient with hemifacial microsomia - A case report.

Authors:  Seon Ju Kim; Haeyeon Lee; Seung Yeon Choi; Bon-Nyeo Koo
Journal:  Anesth Pain Med (Seoul)       Date:  2020-01-31

6.  Does the site of anterior tracheal puncture affect the success rate of retrograde intubation? A prospective, manikin-based study.

Authors:  Eric A Harris; Kristopher L Arheart; Kenneth E Fischler
Journal:  Anesthesiol Res Pract       Date:  2013-06-26

7.  I-Gel versus laryngeal mask airway (LMA) classic as a conduit for tracheal intubation using ventilating bougie.

Authors:  Aditi A Dhimar; Bhavika R Sangada; Mahendra R Upadhyay; Sangita H Patel
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2017 Oct-Dec

8.  Retrograde intubation in a dog with severe temporomandibular joint ankylosis: case report.

Authors:  Verónica Vieitez; Luis Javier Ezquerra; Víctor López Rámis; Massimo Santella; Ignacio Álvarez Gómez de Segura
Journal:  BMC Vet Res       Date:  2018-03-27       Impact factor: 2.741

  8 in total